TY - JOUR
T1 - Gas Temperature Measurement by Aligning Absorption Spectroscopy of Dual- Phase -Unlocked Optical Combs
AU - Zhang, Hongyu
AU - Xu, Lijun
AU - Pang, Yingfei
AU - Cao, Zhang
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2022
Y1 - 2022
N2 - An accurate gas temperature measurement method with dual-phase-unlocked comb absorption spectroscopy was presented. First, the spectra of interferograms (IGMs) of the dual-optical combs were aligned by full-spectrum cross-correlation. The frequency jittering of the spectra relative to the reference spectra was determined by cross-correlation and corrected by spectral shift. Second, a modified multispectral fitting approach was proposed to eliminate the wavelength-dependent intensity difference between the reference and measurement arms. The difference was eliminated to obtain the modified spectra by the differential operation without scaling between the two arms. Then, the gas temperature was calculated from the modified spectra. In the experiment, acetylene in a heatable airtight cell was employed as the target gas, and spectra over 0.8 THz were obtained. In the range from room temperature to 180 °C, the measured temperature agreed linearly with the reference, and the standard deviation of the temperature obtained by averaging 800 spectra for 1 s was less than 1.2 °C. The deviation between the mean value of measured temperatures and reference temperature did not exceed 1.9 °C.
AB - An accurate gas temperature measurement method with dual-phase-unlocked comb absorption spectroscopy was presented. First, the spectra of interferograms (IGMs) of the dual-optical combs were aligned by full-spectrum cross-correlation. The frequency jittering of the spectra relative to the reference spectra was determined by cross-correlation and corrected by spectral shift. Second, a modified multispectral fitting approach was proposed to eliminate the wavelength-dependent intensity difference between the reference and measurement arms. The difference was eliminated to obtain the modified spectra by the differential operation without scaling between the two arms. Then, the gas temperature was calculated from the modified spectra. In the experiment, acetylene in a heatable airtight cell was employed as the target gas, and spectra over 0.8 THz were obtained. In the range from room temperature to 180 °C, the measured temperature agreed linearly with the reference, and the standard deviation of the temperature obtained by averaging 800 spectra for 1 s was less than 1.2 °C. The deviation between the mean value of measured temperatures and reference temperature did not exceed 1.9 °C.
KW - Absorption spectroscopy
KW - dual-optical combs
KW - gas temperature measurement
KW - multispectral fitting
KW - spectral alignment
UR - https://www.scopus.com/pages/publications/85135760688
U2 - 10.1109/TIM.2022.3193181
DO - 10.1109/TIM.2022.3193181
M3 - 文章
AN - SCOPUS:85135760688
SN - 0018-9456
VL - 71
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 7005910
ER -