TY - GEN
T1 - Flow measurement of gaseous CO2 using Averaging Pitot Tubes
AU - Adefila, Kehinde
AU - Yan, Yong
AU - Sun, Lijun
AU - Wang, Tao
PY - 2014
Y1 - 2014
N2 - In this paper, an Averaging Pitot Tube (APT) with Flow Conditioning Wing (FCW) geometry is used as a practical sensing device to measure and characterize the flow of single-phase gaseous CO2. The technique demonstrates a simple, cost-effective and potentially accurate option towards the measurement, accurate accounting and characterization of CO2 in Carbon Capture and Storage pipelines. The metrological performance of the flow sensor is verified using air medium before being applied for gaseous CO2. With a Coriolis mass flow meter acting as a secondary calibration reference to further validate the performance of the APT-FCW flow sensor, both metering instruments were evaluated against a weighing scale apparatus. From experimental and calibration data with air, the APT-FCW's average K-factor and linearity error are found to be 0.5091 and 0.725%, respectively. With operating conditions remaining unaltered in this particular flow measurement application and a target accuracy of ±1%, the error achieved for the Coriolis meter is better than ±0.5% and ±1% for the APT-FCW. Test results and other performance evaluation of the instruments are also discussed.
AB - In this paper, an Averaging Pitot Tube (APT) with Flow Conditioning Wing (FCW) geometry is used as a practical sensing device to measure and characterize the flow of single-phase gaseous CO2. The technique demonstrates a simple, cost-effective and potentially accurate option towards the measurement, accurate accounting and characterization of CO2 in Carbon Capture and Storage pipelines. The metrological performance of the flow sensor is verified using air medium before being applied for gaseous CO2. With a Coriolis mass flow meter acting as a secondary calibration reference to further validate the performance of the APT-FCW flow sensor, both metering instruments were evaluated against a weighing scale apparatus. From experimental and calibration data with air, the APT-FCW's average K-factor and linearity error are found to be 0.5091 and 0.725%, respectively. With operating conditions remaining unaltered in this particular flow measurement application and a target accuracy of ±1%, the error achieved for the Coriolis meter is better than ±0.5% and ±1% for the APT-FCW. Test results and other performance evaluation of the instruments are also discussed.
KW - Carbon capture and storage
KW - Coriolis mass flow meter
KW - averaging pitot tube
KW - flow conditioning wing
UR - https://www.scopus.com/pages/publications/84905717262
U2 - 10.1109/I2MTC.2014.6860972
DO - 10.1109/I2MTC.2014.6860972
M3 - 会议稿件
AN - SCOPUS:84905717262
SN - 9781467363853
T3 - Conference Record - IEEE Instrumentation and Measurement Technology Conference
SP - 1377
EP - 1381
BT - 2014 IEEE International Instrumentation and Measurement Technology Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2014 IEEE International Instrumentation and Measurement Technology Conference: Instrumentation and Measurement for Sustainable Development, I2MTC 2014
Y2 - 12 May 2014 through 15 May 2014
ER -