跳到主要导航 跳到搜索 跳到主要内容

Fitting curve passing through designated point to data for promoting the reproducibility of peripheral quantitative computed tomography (pQCT)

  • Beihang University

科研成果: 书/报告/会议事项章节会议稿件同行评审

摘要

The Peripheral quantitative computed tomography (pQCT) is increasingly being used to monitor bone mineral density (BMD) change in both research and clinical practice in order to evaluate the fracture susceptibility in old people or the effect following therapeutic intervention[3]. In follow-up studies, the drift area (change area) of total cross-sectional area (CSA) comparing with that of the baseline measurement (first measurement) was used to control the position as the baseline measurement. To study the interrelationship between the apparent BMD change and CSA change, the nonlinear regression curve was required to pass through a designated point. However, there is no ready-made software that can give the regression model which can pass through a designated point. In this study, BMD at 21 skeletal locations around 4% length of radius were measured by pQCT, then linear and nonlinear regression models passing through designated point were set up based on least square method using Matlab. The results showed the logarithmic model y = 23.4009-5.92491n(x + 51.9140) was suitable to describe the relationship between BMD change and cross-sectional area (CSA) change at the distal radius. This will be helpful to promote the reproducibility of pQCT in follow-up measurements.

源语言英语
主期刊名BioMedical Engineering and Informatics
主期刊副标题New Development and the Future - Proceedings of the 1st International Conference on BioMedical Engineering and Informatics, BMEI 2008
出版商IEEE Computer Society
867-871
页数5
ISBN(印刷版)9780769531182
DOI
出版状态已出版 - 2008
活动1st International Conference on BioMedical Engineering and Informatics, BMEI 2008, co-located with the 1st International Congress on Image and Signal Processing, CISP 2008 - Sanya, Hainan, 中国
期限: 27 5月 200830 5月 2008

出版系列

姓名BioMedical Engineering and Informatics: New Development and the Future - Proceedings of the 1st International Conference on BioMedical Engineering and Informatics, BMEI 2008
2

会议

会议1st International Conference on BioMedical Engineering and Informatics, BMEI 2008, co-located with the 1st International Congress on Image and Signal Processing, CISP 2008
国家/地区中国
Sanya, Hainan
时期27/05/0830/05/08

学术指纹

探究 'Fitting curve passing through designated point to data for promoting the reproducibility of peripheral quantitative computed tomography (pQCT)' 的科研主题。它们共同构成独一无二的学术指纹。

引用此