TY - JOUR
T1 - Fast reconstruction of computerized tomography images based on the cross-entropy method
AU - Wang, Qi
AU - Wang, Huaxiang
AU - Yan, Yong
PY - 2011/8
Y1 - 2011/8
N2 - Computerized tomography (CT) has been applied to multi-phase flow measurement in recent years. Image reconstruction of CT often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive, especially for the case of on-line flow regime identification. In this paper, a minimum cross-entropy (MCE) reconstruction based on wavelet multi-resolution processing, i.e., an MRMCE method, is proposed for fast reconstruction of CT images. Each row of the system's matrix is transformed by 1-D wavelet decomposition. A regularized MCE solution is obtained using the simultaneous multiplicative algebraic reconstruction technique (SMART) at a coarse resolution level, where important information of the reconstructed image is contained. Then the solution in the finest resolution is obtained by inverse fast wavelet transformation (IFWT). Both computer simulation and experimental work were carried out for oil-gas two-phase flow regimes. Results obtained indicate that the MRMCE method improves the resolution of the reconstructed images and dramatically reduces the computation time compared with the traditional linear back-projection (LBP), MCE and algebraic reconstruction technique (ART) methods. Furthermore, the new method can also be used to accurately estimate the local time-averaged void fraction of dynamic two-phase flow. It is suitable for on-line multi-phase flow measurement.
AB - Computerized tomography (CT) has been applied to multi-phase flow measurement in recent years. Image reconstruction of CT often involves repeatedly solving large-dimensional matrix equations, which are computationally expensive, especially for the case of on-line flow regime identification. In this paper, a minimum cross-entropy (MCE) reconstruction based on wavelet multi-resolution processing, i.e., an MRMCE method, is proposed for fast reconstruction of CT images. Each row of the system's matrix is transformed by 1-D wavelet decomposition. A regularized MCE solution is obtained using the simultaneous multiplicative algebraic reconstruction technique (SMART) at a coarse resolution level, where important information of the reconstructed image is contained. Then the solution in the finest resolution is obtained by inverse fast wavelet transformation (IFWT). Both computer simulation and experimental work were carried out for oil-gas two-phase flow regimes. Results obtained indicate that the MRMCE method improves the resolution of the reconstructed images and dramatically reduces the computation time compared with the traditional linear back-projection (LBP), MCE and algebraic reconstruction technique (ART) methods. Furthermore, the new method can also be used to accurately estimate the local time-averaged void fraction of dynamic two-phase flow. It is suitable for on-line multi-phase flow measurement.
KW - Computerized tomography (CT)
KW - Cross-entropy method
KW - Image reconstruction
KW - Multi-resolution decomposition
KW - Two-phase flow
KW - Wavelet transform
UR - https://www.scopus.com/pages/publications/79957863638
U2 - 10.1016/j.flowmeasinst.2011.03.010
DO - 10.1016/j.flowmeasinst.2011.03.010
M3 - 文章
AN - SCOPUS:79957863638
SN - 0955-5986
VL - 22
SP - 295
EP - 302
JO - Flow Measurement and Instrumentation
JF - Flow Measurement and Instrumentation
IS - 4
ER -