T1 - Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm
AU - Long, Tengyue
AU - Han, Bangcheng
AU - Song, Xinda
AU - Suo, Yuchen
AU - Jia, Le
N1 - Publisher Copyright:
© 2023, The Author(s).
PY - 2023/9
Y1 - 2023/9
N2 - We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x-, y-, and z-axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.
AB - We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x-, y-, and z-axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.
KW - Atomic magnetometer
KW - remanent magnetic field measurement
KW - spin-exchange relaxation free
KW - trisection algorithm
UR - https://www.scopus.com/pages/publications/85153319120
U2 - 10.1007/s13320-023-0684-y