跳到主要导航 跳到搜索 跳到主要内容

Experimental study on the turbine blade cooling channel with crossed-ribs

  • Hong Wu Deng*
  • , Yan Tan
  • , Jia Ren Wang
  • , Ji Ning Sun
  • *此作品的通讯作者
  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

The characteristics of heat transfer and flow resistance in turbine blade cooling channel were studied experimentally with use of vapor heating method, which could provide the experimental model with equivalent wall temperature boundary condition. The experiments were carried out under the condition that the Re was 10000~60000. The experiment models adopted the structure of crossed-ribs, pin-fins and longitudinal dividers. The outside wall was divided into ten regions and the condensation vapor of the regions was gathered to get the local heat transfer coefficient. The results show that the crossed-ribs channel could lead to better heat performance than the pin-fins channel. The results also show that, in the case of Re<30000, the structure with the best general heat transfer performance is crossed-ribs channel of 0612, and in the case of Re>30000, the best one is crossed-ribs channel of 0412.

源语言英语
页(从-至)1931-1937
页数7
期刊Hangkong Dongli Xuebao/Journal of Aerospace Power
25
9
出版状态已出版 - 9月 2010

学术指纹

探究 'Experimental study on the turbine blade cooling channel with crossed-ribs' 的科研主题。它们共同构成独一无二的学术指纹。

引用此