TY - JOUR
T1 - Experimental studies on the performance of magnetic shields under different magnetization conditions
AU - Yang, Jianzhi
AU - Zhang, Xu
AU - Shi, Minxia
AU - Yuan, Shuai
AU - Zhang, Leran
AU - Wang, Ling
AU - Han, Bangcheng
N1 - Publisher Copyright:
© 2023 IOP Publishing Ltd
PY - 2023/5/25
Y1 - 2023/5/25
N2 - In recent decades, magnetic shields have provided basic experimental environments for the measurements of extremely weak magnetic fields represented by the biological magnetic signal. Excellent shielding performances, including the low residual field and high shielding factor (SF), are necessary to ensure the quality of these weak magnetic signals and avoid the interference of external magnetic fields. The magnetic shielding performance of the same device can be affected by different degaussing and test conditions, which remains to be systematically studied. In this paper, experiments with variable magnetization conditions, including different degaussing orders, test fields and environmental fields, are established in a nearly zero-field space to simulate the different situations during measurement. The residual field and SF of the cubic shielding device are tested in these cases. Meanwhile, these shielding performances are analyzed from the perspective of the magnetization state and calculated based on the magnetic properties which are tested and fitted by the Jiles-Atherton model. The results show the influence of these different conditions on the shielding performances of the cubic device, consistent with the numerical calculation. Under the same environmental field, the different degaussing order and test field lead to completely different residual field and shielding performance, respectively. The influence of the Earth’s magnetic field on the SF can be ignored due to its tiny equivalent bias field determined by the anhysteretic magnetization curve.
AB - In recent decades, magnetic shields have provided basic experimental environments for the measurements of extremely weak magnetic fields represented by the biological magnetic signal. Excellent shielding performances, including the low residual field and high shielding factor (SF), are necessary to ensure the quality of these weak magnetic signals and avoid the interference of external magnetic fields. The magnetic shielding performance of the same device can be affected by different degaussing and test conditions, which remains to be systematically studied. In this paper, experiments with variable magnetization conditions, including different degaussing orders, test fields and environmental fields, are established in a nearly zero-field space to simulate the different situations during measurement. The residual field and SF of the cubic shielding device are tested in these cases. Meanwhile, these shielding performances are analyzed from the perspective of the magnetization state and calculated based on the magnetic properties which are tested and fitted by the Jiles-Atherton model. The results show the influence of these different conditions on the shielding performances of the cubic device, consistent with the numerical calculation. Under the same environmental field, the different degaussing order and test field lead to completely different residual field and shielding performance, respectively. The influence of the Earth’s magnetic field on the SF can be ignored due to its tiny equivalent bias field determined by the anhysteretic magnetization curve.
KW - Jiles-Atherton model
KW - degaussing
KW - magnetic shielding
KW - magnetization curve
KW - shielding factor
UR - https://www.scopus.com/pages/publications/85152138376
U2 - 10.1088/1361-6463/acc412
DO - 10.1088/1361-6463/acc412
M3 - 文章
AN - SCOPUS:85152138376
SN - 0022-3727
VL - 56
JO - Journal of Physics D: Applied Physics
JF - Journal of Physics D: Applied Physics
IS - 21
M1 - 215001
ER -