摘要
Due to the absence of domestic automotive exhaust measurement methods, this paper, based on the principle of condensation nucleus growth counting, has developed a nanoparticle counter suitable for automotive exhaust detection. The paper incorporates the peak value counting method and conducts comparative experiments between different counting methods of the nanoparticle counter and the results obtained by electrostatic counting, as well as parallel experiments with a TSI CPC. The following results were obtained: (1) Compared to the traditional rising edge counting method, the peak value counting method significantly improves counting accuracy. (2) When the concentration is below 12, 500 P/cc, the peak value counting method can count more particle signals. (3) In the testing of complex particle clusters in automotive exhaust, the nanoparticle counter can be used for measuring automotive exhaust emissions.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 012027 |
| 期刊 | Journal of Physics: Conference Series |
| 卷 | 2724 |
| 期 | 1 |
| DOI | |
| 出版状态 | 已出版 - 2024 |
| 活动 | 2023 3rd International Conference on Measurement Control and Instrumentation, MCAI 2023 - Hybrid, Guangzhou, 中国 期限: 24 11月 2023 → 26 11月 2023 |
学术指纹
探究 'Experimental research on instrumentation for measuring automotive exhaust particle concentrations' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver