跳到主要导航 跳到搜索 跳到主要内容

Experimental research on instrumentation for measuring automotive exhaust particle concentrations

  • China Jiliang University

科研成果: 期刊稿件会议文章同行评审

摘要

Due to the absence of domestic automotive exhaust measurement methods, this paper, based on the principle of condensation nucleus growth counting, has developed a nanoparticle counter suitable for automotive exhaust detection. The paper incorporates the peak value counting method and conducts comparative experiments between different counting methods of the nanoparticle counter and the results obtained by electrostatic counting, as well as parallel experiments with a TSI CPC. The following results were obtained: (1) Compared to the traditional rising edge counting method, the peak value counting method significantly improves counting accuracy. (2) When the concentration is below 12, 500 P/cc, the peak value counting method can count more particle signals. (3) In the testing of complex particle clusters in automotive exhaust, the nanoparticle counter can be used for measuring automotive exhaust emissions.

源语言英语
文章编号012027
期刊Journal of Physics: Conference Series
2724
1
DOI
出版状态已出版 - 2024
活动2023 3rd International Conference on Measurement Control and Instrumentation, MCAI 2023 - Hybrid, Guangzhou, 中国
期限: 24 11月 202326 11月 2023

学术指纹

探究 'Experimental research on instrumentation for measuring automotive exhaust particle concentrations' 的科研主题。它们共同构成独一无二的学术指纹。

引用此