TY - JOUR
T1 - Experimental investigations of drilling temperature of high-energy ultrasonically assisted bone drilling
AU - Sun, Zhibin
AU - Wang, Yu
AU - Xu, Ke
AU - Zhou, Gang
AU - Liang, Chendi
AU - Qu, Junda
N1 - Publisher Copyright:
© 2019 Elsevier Ltd
PY - 2019/3
Y1 - 2019/3
N2 - Ultrasonically assisted drilling as a new type of bone drilling technology has received increasing attention. However, the vibration energy of existing studies was limited. In this study, a robot-based ultrasonically assisted bone drilling experimental setup was designed, and high-energy ultrasonically assisted bone drilling (vibration frequency=24.1–41 kHz, and vibration amplitude=150–160 µm) was applied to bovine cortical bone to investigate the drilling temperature compared with conventional drilling. The effect of drilling speed on drilling temperature was also studied. The experiment results showed that, compared with the conventional bone drilling, high-energy ultrasonically assisted bone drilling had slightly higher drilling temperature (0.36–0.86 °C), which is in direct contrast to previous reports. We hypothesized that this finding was due to the thermal effect of ultrasonic vibration, which the present study confirmed. Moreover, the drilling temperature increased with higher drilling speed.
AB - Ultrasonically assisted drilling as a new type of bone drilling technology has received increasing attention. However, the vibration energy of existing studies was limited. In this study, a robot-based ultrasonically assisted bone drilling experimental setup was designed, and high-energy ultrasonically assisted bone drilling (vibration frequency=24.1–41 kHz, and vibration amplitude=150–160 µm) was applied to bovine cortical bone to investigate the drilling temperature compared with conventional drilling. The effect of drilling speed on drilling temperature was also studied. The experiment results showed that, compared with the conventional bone drilling, high-energy ultrasonically assisted bone drilling had slightly higher drilling temperature (0.36–0.86 °C), which is in direct contrast to previous reports. We hypothesized that this finding was due to the thermal effect of ultrasonic vibration, which the present study confirmed. Moreover, the drilling temperature increased with higher drilling speed.
KW - Bone drilling
KW - Drilling speed
KW - Drilling temperature
KW - Thermal effect
KW - Ultrasonically assisted drilling
UR - https://www.scopus.com/pages/publications/85060105371
U2 - 10.1016/j.medengphy.2018.12.019
DO - 10.1016/j.medengphy.2018.12.019
M3 - 文章
C2 - 30665747
AN - SCOPUS:85060105371
SN - 1350-4533
VL - 65
SP - 1
EP - 7
JO - Medical Engineering and Physics
JF - Medical Engineering and Physics
ER -