The electrochemical behavior of 00Cr12Ti with different heat treatments in a 0.1 mol·L-1 H2SO4+0.0001 mol·L-1 KSCN solution was investigated by Cu-CuSO4-16%H2SO4 tests, double-loop electrochemical potentiokinetic reactivation (DL-EPR) tests and dynamic electrochemical impedance spectroscopy (DEIS). It was found that specimens treated at 1000°C for 2 h sensitized but specimens treated at 650°C for 2 h did not. The different heat treatments mainly affected the reactivation behavior, but had almost no effect on the activation behavior. During reactivation process, for specimens treated at 1000°C for 2 h, the capacity loop decreased dramatically and then increased gradually, meanwhile it showed a negative value at the low frequency capacitive loop, indicating the breakdown and repair of passive films. For specimens treated at 650°C for 2 h, there were not the breakdown and repair of passive films, meaning that the passive films were stable comparably. After the occurrence of intergranular corrosion, the charge transfer resistance (Rct)of specimens treated at 1000°C for 2 h is much less than the passive film's resistance (Rp) of specimens treated at 650°C for 2 h due to local corrosion in specimens treated at 1000°C for 2 h.

源语言英语
页(从-至)965-971
页数7
期刊Beijing Keji Daxue Xuebao/Journal of University of Science and Technology Beijing
33
8
出版状态已出版 - 8月 2011
已对外发布

学术指纹

探究 'Electrochemical behavior of 00Cr12Ti with different heat treatments during reactivation process' 的科研主题。它们共同构成独一无二的学术指纹。

引用此