Effects of the Pt loading side and cathode-biofilm on the performance of a membrane-less and single-chamber microbial fuel cell

  • Shaoqiang Yang
  • , Boyang Jia
  • , Hong Liu*
  • *此作品的通讯作者
  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

In order to analyze the effect of cathode's Pt loading side on the performance of single-chamber microbial fuel cells (MFCs), power generation of a bamboo charcoal membrane-less air-cathode MFC was examined. The maximum power outputs obtained were 0.144 and 1.16 mW, while the maximum voltage outputs were 0.400 and 0.500 V (external resistance was 500 Ω), respectively, when the Pt loading side facing to the air and to the anode chamber solution; after a long time of operation with the side of cathode loaded Pt facing to anode chamber solution, a biofilm was developed on the inner side of cathode. With the formation of this biofilm, the power outputs of MFC increased first, and then decreased to 0.8 mW; oxidation-reduction potentials (ORP) dropped first, and then achieved the level of stability. Coulombic efficiency (CE) increased at a certain extent. In addition, the impact of cathode-biofilm on the loss of water in anode chamber solution was determined.

源语言英语
页(从-至)1197-1202
页数6
期刊Bioresource Technology
100
3
DOI
出版状态已出版 - 2月 2009

联合国可持续发展目标