摘要
The effect of microwave plasma treatment on corrosion resistance of Ni-base amorphous alloy coatings (Ni-W, Ni-W-B, Ni-Mo-P) was investigated. It was found that the treatment improved their corrosion resistance in H 2SO 4, HNO 3, HCl solutions. The microwave plasma treated ammorphous Ni-W composite coatings (with 5wt% ZrO 2 or Al 2O 3 particles) exhibited higher oxidation resistance during the heating at 700°C for 1-28h. As anodic polarization curve indicated, the microwave plasma treated amorphous Ni-W composite coating had wider passivity potential range. The corrosion resistance of Ni-base amorphous alloy coating was dependent on the power and time of microwave plasma treatment.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 71-XVIII |
| 期刊 | Journal of the Chinese Society of Corrosion and Protection |
| 卷 | 18 |
| 期 | 1 |
| 出版状态 | 已出版 - 1998 |
| 已对外发布 | 是 |