摘要
This work investigated the startup performance of a loop heat pipe (LHP) with non-condensable gas (NCG) under different evaporator tilt angles from -15° to 90°. The working fluid of the tested LHP was ammonia and nitrogen was injected into the LHP to simulate NCG. The main conclusions are summarized as follows: (1) When the tilt angle of evaporator was relatively small, the LHP could operate normally unless there was a large amount of NCG. The reverse flow usual occurred in the case without NCG and could be inhibited in the case with a small amount of NCG; (2) When the tilt angle was relatively large, the LHP could startup successfully with a small amount of NCG but not without NCG. (3) The LHP could not startup when the NCG inventory was large enough at all evaporator tilts.
| 源语言 | 英语 |
|---|---|
| 页 | 1255-1259 |
| 页数 | 5 |
| 出版状态 | 已出版 - 2018 |
| 活动 | CSAA/IET International Conference on Aircraft Utility Systems, AUS 2018 - Guiyang, 中国 期限: 19 6月 2018 → 22 6月 2018 |
会议
| 会议 | CSAA/IET International Conference on Aircraft Utility Systems, AUS 2018 |
|---|---|
| 国家/地区 | 中国 |
| 市 | Guiyang |
| 时期 | 19/06/18 → 22/06/18 |
指纹