跳到主要导航 跳到搜索 跳到主要内容

Dual-Input Transformer: An End-to-End Model for Preoperative Assessment of Pathological Complete Response to Neoadjuvant Chemotherapy in Breast Cancer Ultrasonography

  • Tong Tong
  • , Dongyang Li
  • , Jionghui Gu
  • , Guo Chen
  • , Guotao Bai
  • , Xin Yang
  • , Kun Wang*
  • , Tianan Jiang*
  • , Jie Tian*
  • *此作品的通讯作者
  • CAS - Institute of Automation
  • China Mobile Information Technology Center
  • Beihang University
  • The First Affiliated Hospital, Zhejiang University School of Medicine
  • University of Chinese Academy of Sciences

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

Neoadjuvant chemotherapy (NAC) is the primary method to reduce the burden of tumor and metastasis; in the treatment of breast cancer, it may provide additional opportunities for breast-conserving surgery. Preoperative assessment of pathological complete response (PCR) to NAC is important for developing individualized treatment approaches and predicting patient prognosis. Compared to magnetic resonance imaging (MRI) and mammography, ultrasonography (US) has the advantages of simplicity, flexibility, and real-time imaging. Moreover, it does not require radiation and can provide multi-time acquisition of the tumor during NAC treatment. Recently, deep learning radiomics models based on multi-time-point US images for the prediction of NAC effectiveness have been proposed. To further improve the prediction performance, we carefully designed four supporting modules for our proposed dual-input transformer (DiT): isolated tokens-to-token patch embedding module, shared position embedding, time embedding, and weighted average pooling feature representation modules. The design of each module considers the characteristics of the US images at multiple time points. We validated our model on our retrospective US dataset composed of 484 cases from two centers whose consistency is not sufficiently high. Patients were allocated to training (n = 297), validation (n = 99), and external test (n = 88) sets. The results show that our model can achieve better performance than the Siamese CNN and the standard tokens-to-token vision transformer without using multi-time-point images. The ablation study also proved the effectiveness of each module designed for DiT.

源语言英语
页(从-至)251-262
页数12
期刊IEEE Journal of Biomedical and Health Informatics
卷27
期1
DOI
出版状态已出版 - 1 1月 2023

联合国可持续发展目标

此成果有助于实现下列可持续发展目标:

  1. 可持续发展目标 3 - 良好健康与福祉
    可持续发展目标 3 良好健康与福祉

学术指纹

探究 'Dual-Input Transformer: An End-to-End Model for Preoperative Assessment of Pathological Complete Response to Neoadjuvant Chemotherapy in Breast Cancer Ultrasonography' 的科研主题。它们共同构成独一无二的学术指纹。

引用此