摘要
This paper analyses the transient characteristics and breaking performance of direct-current (DC) forced-interruption vacuum interrupters in 270 V power-supply systems. Three stages are identified in forced interruption: the DC-arcing stage, current-commutation stage, and voltage-recovery stage. During the current-commutation stage, the reverse peak-current coefficient k, which is a key design factor, is used to calculate the rate of current at zero-crossing (di/dt). MATLAB/Simulink simulation models are established to obtain the transient characteristics influenced by the forced-commutation branch parameters and the coefficient k. To study the breaking performance of spiral-type contacts, experiments are conducted for different contact materials and arcing times for currents less than 3.5 kA. During the DC-arcing stage, a locally intensive burning arc is observed in the CuW80 contact; however, it is not observed in the CuCr50 contact. On examining the re-ignition interruption results of the CuW80 contact, the intensive burning arc is found to be positioned within a possible re-ignition region. When the arcing time is longer than 1 ms, the intensive burning arc occurs and affects the breaking performance of the spiral-type contacts. If the DC-arcing stage is prolonged, the total arcing energy increases, which leads to a lower breaking capacity.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 512 |
| 期刊 | Applied Sciences (Switzerland) |
| 卷 | 7 |
| 期 | 6 |
| DOI | |
| 出版状态 | 已出版 - 26 5月 2017 |
指纹
探究 'Direct-current forced interruption and breaking performance of spiral-type contacts in aero applications' 的科研主题。它们共同构成独一无二的指纹。引用此