TY - JOUR
T1 - Development of a novel conductance-based technology for environmental bacterial sensing
AU - Shen, Fang Xia
AU - Tan, Miao Miao
AU - Xu, Hong
AU - Xu, Zhen Cheng
AU - Yao, Mao Sheng
PY - 2013/2
Y1 - 2013/2
N2 - In this study, a simple impedance based technology for measuring bacterial concentrations was developed. The measurement system includes the signal amplification, copper probes and a sample loader. During the experiments, the conductance of Bacillus subtilis var niger, Pseudomonas fluorescens, and Escherichia coli were measured using the combination of a pre-amplifier and a lock-in amplifier. The conductance data were modeled verses the bacterial concentrations. Results indicated that the relationship between the conductance of bacterial suspensions and their concentrations follows a generic model: Y=C1+C2xe(-X/C3), where Y is the conductance (S), X is the bacterial concentration (Number/mL: abbreviated to N/mL) for all species tested, and C1-3 are constants. Gram negative P. fluorescens and E. coli assumed similar conductance curves, which were flatter than that of gram positive B. subtilis var niger. For P. fluorescens and E. coli the culturing technique resulted in higher concentration levels (statistically significant) from 2 to 4 times that measured by the impedance based technology. For B. subtilis var niger, both methods resulted in similar concentration levels. These differences might be due to membrane types, initial culturability and the obtained conductance curves. The impedance based technology here was shown to obtain the bacterial concentration instantly, holding broad promise in realtime monitoring biological agents.
AB - In this study, a simple impedance based technology for measuring bacterial concentrations was developed. The measurement system includes the signal amplification, copper probes and a sample loader. During the experiments, the conductance of Bacillus subtilis var niger, Pseudomonas fluorescens, and Escherichia coli were measured using the combination of a pre-amplifier and a lock-in amplifier. The conductance data were modeled verses the bacterial concentrations. Results indicated that the relationship between the conductance of bacterial suspensions and their concentrations follows a generic model: Y=C1+C2xe(-X/C3), where Y is the conductance (S), X is the bacterial concentration (Number/mL: abbreviated to N/mL) for all species tested, and C1-3 are constants. Gram negative P. fluorescens and E. coli assumed similar conductance curves, which were flatter than that of gram positive B. subtilis var niger. For P. fluorescens and E. coli the culturing technique resulted in higher concentration levels (statistically significant) from 2 to 4 times that measured by the impedance based technology. For B. subtilis var niger, both methods resulted in similar concentration levels. These differences might be due to membrane types, initial culturability and the obtained conductance curves. The impedance based technology here was shown to obtain the bacterial concentration instantly, holding broad promise in realtime monitoring biological agents.
KW - bacterial concentrations
KW - bacterial impedance
KW - bioaerosol
KW - conductance
UR - https://www.scopus.com/pages/publications/84874515326
U2 - 10.1007/s11434-012-5621-1
DO - 10.1007/s11434-012-5621-1
M3 - 文章
AN - SCOPUS:84874515326
SN - 1001-6538
VL - 58
SP - 440
EP - 448
JO - Chinese Science Bulletin
JF - Chinese Science Bulletin
IS - 4-5
ER -