TY - JOUR
T1 - Development and Validation of a Sham-AI Model for Intracranial Aneurysm Detection at CT Angiography
AU - for the China Aneurysm AI Project Group
AU - Shi, Zhao
AU - Hu, Bin
AU - Lu, Mengjie
AU - Zhang, Manting
AU - Yang, Haiting
AU - He, Bo
AU - Ma, Jiyao
AU - Hu, Chunfeng
AU - Lu, Li
AU - Li, Sheng
AU - Ren, Shiyu
AU - Zhang, Yonggao
AU - Li, Jun
AU - Nijiati, Mayidili
AU - Dong, Jiake
AU - Wang, Hao
AU - Zhou, Zhen
AU - Zhang, Fandong
AU - Pan, Chengwei
AU - Yu, Yizhou
AU - Chen, Zijian
AU - Zhou, Chang Sheng
AU - Wei, Yongyue
AU - Zhou, Junlin
AU - Zhang, Long Jiang
N1 - Publisher Copyright:
© 2025, Radiological Society of North America Inc.. All rights reserved.
PY - 2025/5
Y1 - 2025/5
N2 - Purpose: To evaluate a sham–artificial intelligence (AI) model acting as a placebo control for a standard-AI model for diagnosis of intracranial aneurysm. Materials and Methods: This retrospective crossover, blinded, multireader, multicase study was conducted from November 2022 to March 2023. A sham-AI model with near-zero sensitivity and similar specificity to a standard AI model was developed using 16 422 CT angiography examinations. Digital subtraction angiography–verified CT angiographic examinations from four hospitals were collected, half of which were processed by standard AI and the others by sham AI to generate sequence A; sequence B was generated in the reverse order. Twenty-eight radiologists from seven hospitals were randomly assigned to either sequence and then assigned to the other sequence after a washout period. The diagnostic performances of radiologists alone, radiologists with standard-AI assistance, and radiologists with sham-AI assistance were compared using sensitivity and specificity, and radiologists’ susceptibility to sham AI suggestions was assessed. Results: The testing dataset included 300 patients (median age, 61.0 years [IQR, 52.0–67.0]; 199 male), 50 of whom had aneurysms. Standard AI and sham AI performed as expected (sensitivity, 96.0% vs 0.0%; specificity, 82.0% vs 76.0%). The differences in sensitivity and specificity between standard AI–assisted and sham AI–assisted readings were 20.7% (95% CI: 15.8, 25.5 [superiority]) and 0.0% (95% CI: −2.0, 2.0 [noninferiority]), respectively. The difference between sham AI–assisted readings and radiologists alone was −2.6% (95% CI: −3.8, −1.4 [noninferiority]) for both sensitivity and specificity. After sham-AI suggestions, 5.3% (44 of 823) of true-positive and 1.2% (seven of 577) of false-negative results of radiologists alone were changed. Conclusion: Radiologists’ diagnostic performance was not compromised when aided by the proposed sham-AI model compared with their unassisted performance.
AB - Purpose: To evaluate a sham–artificial intelligence (AI) model acting as a placebo control for a standard-AI model for diagnosis of intracranial aneurysm. Materials and Methods: This retrospective crossover, blinded, multireader, multicase study was conducted from November 2022 to March 2023. A sham-AI model with near-zero sensitivity and similar specificity to a standard AI model was developed using 16 422 CT angiography examinations. Digital subtraction angiography–verified CT angiographic examinations from four hospitals were collected, half of which were processed by standard AI and the others by sham AI to generate sequence A; sequence B was generated in the reverse order. Twenty-eight radiologists from seven hospitals were randomly assigned to either sequence and then assigned to the other sequence after a washout period. The diagnostic performances of radiologists alone, radiologists with standard-AI assistance, and radiologists with sham-AI assistance were compared using sensitivity and specificity, and radiologists’ susceptibility to sham AI suggestions was assessed. Results: The testing dataset included 300 patients (median age, 61.0 years [IQR, 52.0–67.0]; 199 male), 50 of whom had aneurysms. Standard AI and sham AI performed as expected (sensitivity, 96.0% vs 0.0%; specificity, 82.0% vs 76.0%). The differences in sensitivity and specificity between standard AI–assisted and sham AI–assisted readings were 20.7% (95% CI: 15.8, 25.5 [superiority]) and 0.0% (95% CI: −2.0, 2.0 [noninferiority]), respectively. The difference between sham AI–assisted readings and radiologists alone was −2.6% (95% CI: −3.8, −1.4 [noninferiority]) for both sensitivity and specificity. After sham-AI suggestions, 5.3% (44 of 823) of true-positive and 1.2% (seven of 577) of false-negative results of radiologists alone were changed. Conclusion: Radiologists’ diagnostic performance was not compromised when aided by the proposed sham-AI model compared with their unassisted performance.
KW - CT Angiography
KW - Intracranial Aneurysm
KW - Sham AI
KW - Vascular
UR - https://www.scopus.com/pages/publications/105007570052
U2 - 10.1148/ryai.240140
DO - 10.1148/ryai.240140
M3 - 文章
AN - SCOPUS:105007570052
SN - 2638-6100
VL - 7
JO - Radiology: Artificial Intelligence
JF - Radiology: Artificial Intelligence
IS - 3
M1 - 240140