TY - JOUR
T1 - Deuterium retention and desorption behavior of W-Ta-Cr-V high entropy alloy
AU - Shi, Yongzhi
AU - Jiang, Zhenyu
AU - Xia, Tongjun
AU - Wang, Zizhao
AU - Wu, Jianwei
AU - Cao, Xingzhong
AU - Zhu, Kaigui
N1 - Publisher Copyright:
© 2022
PY - 2022/9
Y1 - 2022/9
N2 - Deuterium retention and desorption behavior of W-Ta-Cr-V films under deuterium plasma irradiation were studied. The W-Ta-Cr-V films were prepared on the molybdenum (Mo) substrate by magnetron sputtering. Subsequently, all films annealed at 1000 °C were exposed to deuterium plasma at a flux of 8.13 × 1019 D/m2·s for 9 h to achieve an irradiation fluence of 2.63 ×1024 D/m2. Electron backscattered diffraction (EBSD) was used to characterize the texture and average grain size of films. Doppler broadening spectrometry of positron annihilation (DBS-PA) was carried out with an energy-variable slow positron beam to detect the concentration of vacancy-type defects in the films. The results suggest that there are fewer vacancy-type defects inside W-Ta-Cr-V grains. Deuterium retention and the desorption behavior of W-Ta-Cr-V were studied by compared to pure tungsten films. In the 300–800 K temperature range, the peaks of thermal desorption spectroscopy (TDS) of W-Ta-Cr-V films are substantially consistent with that of the W films. Notably, in the range of 800 K-1000 K, W-Ta-Cr-V film has no thermal desorption peak. We attribute this to the large lattice distortion and low vacancy formation energy, which inhibit the growth of voids inside the grains of W-Ta-Cr-V films. The total deuterium retention of W-Ta-Cr-V films is compared with that of W films. It is measured by TDS that the deuterium retention of W-Ta-Cr-V films is nearly 5 times that of W films. Based on the analysis of the TDS spectra, the higher deuterium retention in W-Ta-Cr-V films is due to the more grain boundary defects.
AB - Deuterium retention and desorption behavior of W-Ta-Cr-V films under deuterium plasma irradiation were studied. The W-Ta-Cr-V films were prepared on the molybdenum (Mo) substrate by magnetron sputtering. Subsequently, all films annealed at 1000 °C were exposed to deuterium plasma at a flux of 8.13 × 1019 D/m2·s for 9 h to achieve an irradiation fluence of 2.63 ×1024 D/m2. Electron backscattered diffraction (EBSD) was used to characterize the texture and average grain size of films. Doppler broadening spectrometry of positron annihilation (DBS-PA) was carried out with an energy-variable slow positron beam to detect the concentration of vacancy-type defects in the films. The results suggest that there are fewer vacancy-type defects inside W-Ta-Cr-V grains. Deuterium retention and the desorption behavior of W-Ta-Cr-V were studied by compared to pure tungsten films. In the 300–800 K temperature range, the peaks of thermal desorption spectroscopy (TDS) of W-Ta-Cr-V films are substantially consistent with that of the W films. Notably, in the range of 800 K-1000 K, W-Ta-Cr-V film has no thermal desorption peak. We attribute this to the large lattice distortion and low vacancy formation energy, which inhibit the growth of voids inside the grains of W-Ta-Cr-V films. The total deuterium retention of W-Ta-Cr-V films is compared with that of W films. It is measured by TDS that the deuterium retention of W-Ta-Cr-V films is nearly 5 times that of W films. Based on the analysis of the TDS spectra, the higher deuterium retention in W-Ta-Cr-V films is due to the more grain boundary defects.
KW - Deuterium plasma irradiation
KW - Deuterium retention
KW - High-entropy alloy films
KW - Magnetron Sputtering
KW - Tungsten films
UR - https://www.scopus.com/pages/publications/85133716146
U2 - 10.1016/j.jnucmat.2022.153897
DO - 10.1016/j.jnucmat.2022.153897
M3 - 文章
AN - SCOPUS:85133716146
SN - 0022-3115
VL - 568
JO - Journal of Nuclear Materials
JF - Journal of Nuclear Materials
M1 - 153897
ER -