跳到主要导航 跳到搜索 跳到主要内容

Determination of temperature recovery time in differential-pressure-based air leak detector

  • L. G. Harus*
  • , Maolin Cai
  • , Kenji Kawashima
  • , Toshiharu Kagawa
  • *此作品的通讯作者
  • Institute of Science Tokyo

科研成果: 期刊稿件文章同行评审

摘要

Repeatability and accuracy in a differential-pressure-based air leak detector can be increased by providing adequate temperature recovery time to the system after the charging process. However, different volumes and applied pressures need different temperature recovery times. We proposed a method to accurately predict the minimum required temperature recovery time considering repeatability and accuracy of the leak detector by investigating the relation between temperature recovery time and theoretical thermal-time constant for various test volumes and applied pressures. To demonstrate the effectiveness of the proposed method, a differential-pressure-based air leak detector is developed. In this method, a leak is simply detected by measuring the differential pressure between a leak-tight master and a test chamber. The results show that the minimum required temperature recovery time to produce repeatability and accuracy not less than 1.67 × 10-11 m 3 s-1 for various applied pressures and volumes is proportional to six times the theoretical thermal-time constant.

源语言英语
页(从-至)411-418
页数8
期刊Measurement Science and Technology
17
2
DOI
出版状态已出版 - 1 2月 2006
已对外发布

指纹

探究 'Determination of temperature recovery time in differential-pressure-based air leak detector' 的科研主题。它们共同构成独一无二的指纹。

引用此