TY - GEN
T1 - Detection and analysis of high voltage electrical equipment corona discharge based on ultraviolet imaging technology
AU - Yongxiang, Li
AU - Tianzheng, Wang
AU - Liqiang, Guo
AU - Zhipeng, Wang
AU - Ting, Guo
AU - Xueting, Cheng
N1 - Publisher Copyright:
© 2017 IEEE.
PY - 2017/7/12
Y1 - 2017/7/12
N2 - The corona discharge phenomena of electrical equipment are generated with the increasing of insulation aging, electrical equipment, surface filth or atmospheric humidity. The corona discharge will cause the waste of power energy, radio interference, audible noise, insulation aging, and these defects are great threats to the safety and stability of electrical equipment. Using appropriate method to detect the operational state of electrical equipment is always significantly concerned by operation department. In this paper, the different corona discharge defect part of high voltage electrical equipment are summarized such as the grading ring, drop wire, jumper and over line, spacing rods, tube bus end and connecting joint. While the photon numbers of corona discharge under different defects are measured by the ultraviolet imager. The result shows that: the corona discharge characteristics of electrical equipment are different under the different defect type, and the photon number increases with the rising of the applied voltage. The detected photon number varies with different kinds of defects through applying same voltage. The ultraviolet imager shows the excellent performance in the detection of discharge defects and thus it can be prospectively used in the operation state detection of electrical equipment.
AB - The corona discharge phenomena of electrical equipment are generated with the increasing of insulation aging, electrical equipment, surface filth or atmospheric humidity. The corona discharge will cause the waste of power energy, radio interference, audible noise, insulation aging, and these defects are great threats to the safety and stability of electrical equipment. Using appropriate method to detect the operational state of electrical equipment is always significantly concerned by operation department. In this paper, the different corona discharge defect part of high voltage electrical equipment are summarized such as the grading ring, drop wire, jumper and over line, spacing rods, tube bus end and connecting joint. While the photon numbers of corona discharge under different defects are measured by the ultraviolet imager. The result shows that: the corona discharge characteristics of electrical equipment are different under the different defect type, and the photon number increases with the rising of the applied voltage. The detected photon number varies with different kinds of defects through applying same voltage. The ultraviolet imager shows the excellent performance in the detection of discharge defects and thus it can be prospectively used in the operation state detection of electrical equipment.
KW - Corona Discharge and Case Analysis
KW - High Voltage Equipment
KW - Ultraviolet Imaging Technology
UR - https://www.scopus.com/pages/publications/85028041431
U2 - 10.1109/CCDC.2017.7978429
DO - 10.1109/CCDC.2017.7978429
M3 - 会议稿件
AN - SCOPUS:85028041431
T3 - Proceedings of the 29th Chinese Control and Decision Conference, CCDC 2017
SP - 6928
EP - 6931
BT - Proceedings of the 29th Chinese Control and Decision Conference, CCDC 2017
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 29th Chinese Control and Decision Conference, CCDC 2017
Y2 - 28 May 2017 through 30 May 2017
ER -