TY - GEN
T1 - Design of Self-Shielded Uniform Magnetic Field Coil based on Improved TFM
AU - Pang, Haoying
AU - Fan, Wenfeng
AU - Wang, Jing
AU - Liu, Feng
AU - Wu, Zhihong
AU - Yuan, Qi
N1 - Publisher Copyright:
© 2022 IEEE.
PY - 2022
Y1 - 2022
N2 - Aiming at the influence of the magnetic shielding cylinder on the coil performance in the atomic sensor, a transverse self-shield uniform field coil is obtained by using improved target field method (TFM). The coil consists of two coaxial coils that produce the uniform field in the coil center, and the field decays rapidly to zero outside the coil. Based on the improved TFM, the current densities are expanded into triangular series and their Fourier coefficients are obtained from the target field point expected value. Compared with the traditional design method, this method can determine the winding form according to the desired target, and can obtain better uniformity. Through numerical simulation, the designed self-shielded coil has a uniformity of 6.1× 10-4 in the target area, and has outstanding self-shielded effect. This paper not only improves the uniformity, but also further solves the coupling problem between the coil and shield. This is beneficial to the performance improvement of the magnetic compensation system in atomic sensors.
AB - Aiming at the influence of the magnetic shielding cylinder on the coil performance in the atomic sensor, a transverse self-shield uniform field coil is obtained by using improved target field method (TFM). The coil consists of two coaxial coils that produce the uniform field in the coil center, and the field decays rapidly to zero outside the coil. Based on the improved TFM, the current densities are expanded into triangular series and their Fourier coefficients are obtained from the target field point expected value. Compared with the traditional design method, this method can determine the winding form according to the desired target, and can obtain better uniformity. Through numerical simulation, the designed self-shielded coil has a uniformity of 6.1× 10-4 in the target area, and has outstanding self-shielded effect. This paper not only improves the uniformity, but also further solves the coupling problem between the coil and shield. This is beneficial to the performance improvement of the magnetic compensation system in atomic sensors.
KW - Atomic sensors
KW - improved target field method
KW - self-shielded
KW - uniform field
UR - https://www.scopus.com/pages/publications/85147906786
U2 - 10.1109/YAC57282.2022.10023873
DO - 10.1109/YAC57282.2022.10023873
M3 - 会议稿件
AN - SCOPUS:85147906786
T3 - Proceedings - 2022 37th Youth Academic Annual Conference of Chinese Association of Automation, YAC 2022
SP - 553
EP - 556
BT - Proceedings - 2022 37th Youth Academic Annual Conference of Chinese Association of Automation, YAC 2022
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 37th Youth Academic Annual Conference of Chinese Association of Automation, YAC 2022
Y2 - 19 November 2022 through 20 November 2022
ER -