摘要
A dc-link voltage balancing control strategy for quasi-Z-source cascaded H-bridge (qZS-CHB) inverter photovoltaic (PV) power system is proposed by using multidimensional pulse-width modulation (MD-PWM) technique. The qZS-CHB PV system usually employs proportional-integral (PI) regulators based closed-loop control methods to balance dc-link voltages, combining with distributed maximum power point tracking and grid-Tie power control. These require significant control computations and hardware resources for multiple modules based qZS-CHB system. The proposed MD-PWM for the qZS-CHB inverter performs shoot-Through behavior based on geometric representation of the output voltage ranges of each H-bridge in coordinate axes. All possible switching sequences of the qZS-CHB inverter are taken into account to choose the most suitable sequence that can balance dc-link voltages of qZS modules in the qZS-CHB PV power system. When compared with the state-of-The-Art of voltage balancing control methods, the proposed control strategy has advantages: 1) The computation is low because there is no PI controller, while the stability of the whole system is improved; and 2) there is a reliable balancing capability with fast regulation of dc-link voltages, owing to no extra controller parameters and handling the voltage balance in each control cycle. Simulation and experimental results of qZS-CHB inverter based grid-Tie PV power system verify the proposed dc-link voltage balancing control technique.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 8426012 |
| 页(从-至) | 4905-4915 |
| 页数 | 11 |
| 期刊 | IEEE Transactions on Industrial Informatics |
| 卷 | 14 |
| 期 | 11 |
| DOI | |
| 出版状态 | 已出版 - 11月 2018 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 7 经济适用的清洁能源
指纹
探究 'DC-Link Voltage Balance Control Strategy Based on Multidimensional Modulation Technique for Quasi-Z-Source Cascaded Multilevel Inverter Photovoltaic Power System' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver