摘要
Differential scanning calorimetry (DSC) in dynamic and isothermal modes performs an analysis of the cure kinetics of a modified BMI system. The system used in this study is the 4,4'-bismaleimidodiphenyl-methane (BMIM) and 0,0'-diallyl bisphenol A (DABPA, DABA). All experimental data in different temperatures are analysed by n-th cure reaction model. Reaction mechanism function is determined by Sharp et al. method. The other parameters such as activation energy and frequency factor are characterized by least square method. The experimental result shows that the first order kinetic expression correctly represents to analyze the cure kinetics of this system.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 1375-1377+1381 |
| 期刊 | Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology |
| 卷 | 36 |
| 期 | 10 |
| 出版状态 | 已出版 - 10月 2004 |
| 已对外发布 | 是 |