跳到主要导航 跳到搜索 跳到主要内容

CT perfusion parameter estimation in stroke using neural network with transformer and physical model priors

  • Luyao Luo
  • , Pan Liu
  • , Wanxing Ye
  • , Fengwei Chen
  • , Yu Liu
  • , Ziyang Liu
  • , Jing Jing
  • , Yunyun Xiong
  • , Wanlin Zhu
  • , Yong Jiang
  • , Jian Cheng
  • , Yongjun Wang
  • , Tao Liu*
  • *此作品的通讯作者
  • Beihang University
  • General Hospital of People's Liberation Army
  • Capital Medical University

科研成果: 期刊稿件文章同行评审

摘要

Objectives: CT perfusion (CTP) imaging is vital in treating acute ischemic stroke by identifying salvageable tissue and the infarcted core. CTP images allow quantitative estimation of CT perfusion parameters, which can provide information on the degree of tissue hypoperfusion and its salvage potential. Traditional methods for estimating perfusion parameters, such as singular value decomposition (SVD) and its variations, are known to be sensitive to noise and inaccuracies in the arterial input function. To our knowledge, there has been no implementation of deep learning methods for CT perfusion parameter estimation. Materials & methods: In this work, we propose a deep learning method based on the Transformer model, named CTPerformer-Net, for CT perfusion parameter estimation. In addition, our method incorporates some physical priors. We integrate physical consistency prior, smoothness prior and the physical model prior through the design of the loss function. We also generate a simulation dataset based on physical model prior for training the network model. Results: In the simulation dataset, CTPerformer-Net exhibits a 23.4 % increase in correlation coefficients, a 95.2 % decrease in system error, and a 90.7 % reduction in random error when contrasted with block-circulant SVD. CTPerformer-Net successfully identifies hypoperfused and infarcted lesions in 103 real CTP images from the ISLES 2018 challenge dataset. It achieves a mean dice score of 0.36 for the infarct core segmentation, which is slightly higher than the commercially available software (dice coefficient: 0.34) used as a reference level by the challenge. Conclusion: Experimental results on the simulation dataset demonstrate that CTPerformer-Net achieves better performance compared to block-circulant SVD. The real-world patient dataset confirms the validity of CTPerformer-Net.

源语言英语
文章编号109134
期刊Computers in Biology and Medicine
182
DOI
出版状态已出版 - 11月 2024

学术指纹

探究 'CT perfusion parameter estimation in stroke using neural network with transformer and physical model priors' 的科研主题。它们共同构成独一无二的学术指纹。

引用此