跳到主要导航 跳到搜索 跳到主要内容

Cooling effectiveness in a rotor-stator system with different pre-swirl angles

  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

An experimental study of the flow and heat transfer characteristics in a pre-swirl rotor-stator system was described. Pre-swirl cooling air through nozzles in the stator flowed radially outwards and left system from the clearance between rotor and stator. Three kinds of pre-swirl nozzles (orifice angle of inclination at 0°, 15°, and 30°) were applied to study cooling effects of pre-swirl flow on the rotating disk. Some parameters including distributions of temperature, local and averaged Nusselt number, dimensionless excessive body average temperature and dimensionless radial temperature difference were measured in the tests. It shows that the nozzle with 0° angle of inclination has the highest cooling effectiveness, followed by the 15° nozzle and then the 30° nozzle. The cooling flow rate plays a more important role on cooling effectiveness than rotating speed.

源语言英语
页(从-至)240-243
页数4
期刊Tuijin Jishu/Journal of Propulsion Technology
28
3
出版状态已出版 - 6月 2007