TY - JOUR
T1 - Comprehensive analysis on the magnetic field error of a K–Rb–21Ne comagnetometer with low-frequency bias magnetic field sensitivity
AU - Wu, Zhihong
AU - Liu, Feng
AU - Wang, Zhuo
AU - Fan, Wenfeng
AU - Pang, Haoying
AU - Quan, Wei
N1 - Publisher Copyright:
Copyright © 2023 Wu, Liu, Wang, Fan, Pang and Quan.
PY - 2023
Y1 - 2023
N2 - The spin-exchange relaxation-free comagnetometer (SERFC) is of important research value compared to existing high-precision gyroscopes because of its extremely high theoretical limit sensitivity and long-term stability, in which one significant limiting factor is the magnetic field error. First, the relationship between the magnetic field gradient and the nuclear spin relaxation mechanism is introduced into the frequency response and steady-state response models of SERFC. Then, a novel method for suppression of the low-frequency magnetic field error based on the modified bias magnetic field sensitivity model is proposed. Finally, the effectiveness of the proposed suppression methods is demonstrated by optimizing the cell temperature, pump light power, and compensation magnetic field gradient to increase the suppression factor by 72.19%, 20.24%, and 69.86%, and the corresponding bias instability increased by 55.41%, 20.84%, and 27.63%, respectively. This study contributes to improving the long-term zero bias stability of the SERFC.
AB - The spin-exchange relaxation-free comagnetometer (SERFC) is of important research value compared to existing high-precision gyroscopes because of its extremely high theoretical limit sensitivity and long-term stability, in which one significant limiting factor is the magnetic field error. First, the relationship between the magnetic field gradient and the nuclear spin relaxation mechanism is introduced into the frequency response and steady-state response models of SERFC. Then, a novel method for suppression of the low-frequency magnetic field error based on the modified bias magnetic field sensitivity model is proposed. Finally, the effectiveness of the proposed suppression methods is demonstrated by optimizing the cell temperature, pump light power, and compensation magnetic field gradient to increase the suppression factor by 72.19%, 20.24%, and 69.86%, and the corresponding bias instability increased by 55.41%, 20.84%, and 27.63%, respectively. This study contributes to improving the long-term zero bias stability of the SERFC.
KW - bias magnetic field sensitivity
KW - comagnetometer
KW - low-frequency magnetic error
KW - magnetic field gradient
KW - spin-exchange relaxation-free
UR - https://www.scopus.com/pages/publications/85163033131
U2 - 10.3389/fphy.2023.1201365
DO - 10.3389/fphy.2023.1201365
M3 - 文章
AN - SCOPUS:85163033131
SN - 2296-424X
VL - 11
JO - Frontiers in Physics
JF - Frontiers in Physics
M1 - 1201365
ER -