摘要

In this paper, an ECT sensor with 12 external electrodes and 4 internal electrodes (IEE) is designed to investigate the quality of reconstructed images in circular and annular areas. The sensitivity distribution and the capacitance between different electrode pairs are calculated using a finite element method (FEM), and then used to reconstruct images using Landweber iteration algorithm. For the circular area, three different measuring strategies are considered, and then compared with a traditional ECT sensor (EE). For the annular area, three different measuring strategies, the internal electrode with/without screen, the EE sensor are considered and compared. The results show that, the IEE sensor can improve the image quality in circular areas, and only in certain circumstances, the IEE sensor can improve the image quality in annular areas comparing with the EE sensor.

源语言英语
主期刊名IST 2013 - 2013 IEEE International Conference on Imaging Systems and Techniques, Proceedings
31-34
页数4
DOI
出版状态已出版 - 2013
已对外发布
活动2013 IEEE International Conference on Imaging Systems and Techniques, IST 2013 - Beijing, 中国
期限: 22 10月 201323 10月 2013

出版系列

姓名IST 2013 - 2013 IEEE International Conference on Imaging Systems and Techniques, Proceedings

会议

会议2013 IEEE International Conference on Imaging Systems and Techniques, IST 2013
国家/地区中国
Beijing
时期22/10/1323/10/13