TY - JOUR
T1 - Combination of a simplified one-dimensional human thermoregulatory model with the water circulation temperature control and RO membrane sweating systems in the thermal manikin
AU - Nie, Jiachen
AU - Ding, Li
AU - Tian, Yinsheng
AU - Xue, Lihao
AU - Zhang, Qing
AU - Yi, Fahui
N1 - Publisher Copyright:
© 2022 Elsevier Masson SAS
PY - 2023/2
Y1 - 2023/2
N2 - Thermal manikins are widely applied in evaluating thermal properties of personal protective equipment and environments, but their adaptability to transient environments are limited to the control algorithm and hardware of the heating and sweating system. This study aims to design and instrument a novel regional thermal manikin system that can automatically regulate the skin temperature and sweating rate under transient environments. A simplified one-dimensional human thermoregulatory model, the water circulation temperature control and RO membrane sweating systems were established to an integrated temperature and sweating control system (ITSCS) in the left calf segment with critical indicators tested. Results demonstrated that the sweating rate, response time and temperature incrementing and declining speeds were reliable for dynamic regulation in thermal manikins, while the control accuracy was acceptable, and average skin temperature deviations in ITSCS from simulation did not exceed 0.2 °C. Thus the ITSCS can be applied to simulate human thermophysiological responses under transient environments.
AB - Thermal manikins are widely applied in evaluating thermal properties of personal protective equipment and environments, but their adaptability to transient environments are limited to the control algorithm and hardware of the heating and sweating system. This study aims to design and instrument a novel regional thermal manikin system that can automatically regulate the skin temperature and sweating rate under transient environments. A simplified one-dimensional human thermoregulatory model, the water circulation temperature control and RO membrane sweating systems were established to an integrated temperature and sweating control system (ITSCS) in the left calf segment with critical indicators tested. Results demonstrated that the sweating rate, response time and temperature incrementing and declining speeds were reliable for dynamic regulation in thermal manikins, while the control accuracy was acceptable, and average skin temperature deviations in ITSCS from simulation did not exceed 0.2 °C. Thus the ITSCS can be applied to simulate human thermophysiological responses under transient environments.
KW - Adaptive thermal manikins
KW - Control accuracy
KW - RO membrane Sweating system
KW - Response time
KW - Thermoregulatory model
KW - Water circulation temperature control system
UR - https://www.scopus.com/pages/publications/85138382667
U2 - 10.1016/j.ijthermalsci.2022.107941
DO - 10.1016/j.ijthermalsci.2022.107941
M3 - 文章
AN - SCOPUS:85138382667
SN - 1290-0729
VL - 184
JO - International Journal of Thermal Sciences
JF - International Journal of Thermal Sciences
M1 - 107941
ER -