TY - JOUR
T1 - CD-Net
T2 - Comprehensive Domain Network with Spectral Complementary for DECT Sparse-View Reconstruction
AU - Zhang, Yikun
AU - Lv, Tianling
AU - Ge, Rongjun
AU - Zhao, Qianlong
AU - Hu, Dianlin
AU - Zhang, Liu
AU - Liu, Jin
AU - Zhang, Yi
AU - Liu, Qiegen
AU - Zhao, Wei
AU - Chen, Yang
N1 - Publisher Copyright:
© 2015 IEEE.
PY - 2021
Y1 - 2021
N2 - Dual-energy computed tomography (DECT) is of great clinical significance because of its material identification and quantification capacity. Although DECT measures attenuation using two different spectra, the anatomical structure of the low- and high-energy CT images are consistent with each other and the images are also correlated in the energy domain, resulting in significant information redundancy. Here this redundancy has been exploited by the proposed CD-Net (Comprehensive Domain Network) with spectral complementarity to improve the image quality and reduce the radiation dose for DECT imaging. CD-Net restores accurate anatomical information from both projection and image domains. It encompasses a projection domain neural network (PD-Net), an analytical reconstruction operator (ARO) and an image domain neural network (ID-Net). Embedding ARO into deep learning framework, the proposed one-step DECT sparse reconstruction method can directly produce high-quality DECT images from projection data acquired with spectral complementarity scheme. Qualitative and quantitative analyses demonstrate the competitive performance of CD-Net in terms of CT number accuracy, detail preservation and artifact removal. Two popular DECT applications, virtual non-contrast (VNC) imaging and iodine contrast agent quantification, reveal that the images reconstructed by CD-Net are promising for clinical applications.
AB - Dual-energy computed tomography (DECT) is of great clinical significance because of its material identification and quantification capacity. Although DECT measures attenuation using two different spectra, the anatomical structure of the low- and high-energy CT images are consistent with each other and the images are also correlated in the energy domain, resulting in significant information redundancy. Here this redundancy has been exploited by the proposed CD-Net (Comprehensive Domain Network) with spectral complementarity to improve the image quality and reduce the radiation dose for DECT imaging. CD-Net restores accurate anatomical information from both projection and image domains. It encompasses a projection domain neural network (PD-Net), an analytical reconstruction operator (ARO) and an image domain neural network (ID-Net). Embedding ARO into deep learning framework, the proposed one-step DECT sparse reconstruction method can directly produce high-quality DECT images from projection data acquired with spectral complementarity scheme. Qualitative and quantitative analyses demonstrate the competitive performance of CD-Net in terms of CT number accuracy, detail preservation and artifact removal. Two popular DECT applications, virtual non-contrast (VNC) imaging and iodine contrast agent quantification, reveal that the images reconstructed by CD-Net are promising for clinical applications.
KW - Deep learning
KW - dual-energy computed tomography
KW - iodine quantification
KW - one-step
KW - sparse-view reconstruction
KW - virtual non-contrast
UR - https://www.scopus.com/pages/publications/85103788463
U2 - 10.1109/TCI.2021.3070184
DO - 10.1109/TCI.2021.3070184
M3 - 文章
AN - SCOPUS:85103788463
SN - 2333-9403
VL - 7
SP - 436
EP - 447
JO - IEEE Transactions on Computational Imaging
JF - IEEE Transactions on Computational Imaging
M1 - 9393559
ER -