摘要
In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV magnetometer attains a magnetic sensitivity of 4.3 nT / H z and a volume-normalized sensitivity of 3.6 pT / H z mm - 3, which are ∼five times better than the already existing method under the same conditions. Based on the proposed magnetometer configuration, a burst eddy current testing prototype achieves a minimum detectable sample smaller than 300 μ m and a spatial resolution of 470 μ m, which is employed to image different metallic specimens and detect layered internal structures. Since this prototype comprises remarkable high sensitivity, it exhibits various potential applications in the fields of security screening and quality control. Moreover, its biocompatibility and promising nanoscale resolution pave the way for electromagnetic testing in the fields of biomaterials.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 084104 |
| 期刊 | Applied Physics Letters |
| 卷 | 120 |
| 期 | 8 |
| DOI | |
| 出版状态 | 已出版 - 21 2月 2022 |
指纹
探究 'Burst eddy current testing with diamond magnetometry' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver