跳到主要导航 跳到搜索 跳到主要内容

Biomechanical study of lumbar spine under different vibration conditions

科研成果: 期刊稿件文章同行评审

摘要

We observed the effect of vibration parameters on lumbar spine under different vibration conditions using finite element analysis method in our laboratory. In this study, the CT-images of L1-L5 segments were obtained. All images were used to develop 3D geometrical model using the Mimics10. 01 (Materialise, Belgium). Then it was modified using Geomagic Studio12. 0 (Raindrop Geomagic Inc. USA). Finite element (FE) mesh model was generated by Hypermesh11. 0 (Altair Engineering, Inc. USA) and Abaqus. Abaqus was used to calculate the stress distribution of L1-L5 under different vibration conditions. It was found that in a vibration cycle, tensile stress was occurred on lumbar vertebra mainly. Stress distributed evenly and stress concentration occurred on the left rear side of the upper endplate. The stress had no obvious changes under different frequencies, but the stress was higher when amplitude was greater. In conclusion, frequency and amplitude parameters have little effect on the stress distribution in vertebra. The stress magnitude is positively correlated with the amplitude.

源语言英语
页(从-至)48-54
页数7
期刊Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering
32
1
出版状态已出版 - 1 2月 2015

学术指纹

探究 'Biomechanical study of lumbar spine under different vibration conditions' 的科研主题。它们共同构成独一无二的学术指纹。

引用此