摘要
In June 2008, the Shenzhen landfill slope failed. This case is used as an example to study the deformation characteristics and failure mode of a slope induced by high water levels. An integrated monitoring system, including water level gauges, electronic total stations, and inclinometers, was used to monitor the slope failure process. The field measurements suggest that the landfill landslide was caused by a deep slip along the weak interface of the composite liner system at the base of the landfill. The high water level is considered to be the main factor that caused this failure. To calculate the relative interface shear displacements in the geosynthetic multilayer liner system, a series of numerical direct shear tests were carried out. Based on the numerical results, the composite lining system simplified and the centrifuge modeling technique was used to quantitatively evaluate the effect of water levels on landfill instability.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 126 |
| 期刊 | International Journal of Environmental Research and Public Health |
| 卷 | 13 |
| 期 | 1 |
| DOI | |
| 出版状态 | 已出版 - 12 1月 2016 |
联合国可持续发展目标
此成果有助于实现下列可持续发展目标:
-
可持续发展目标 3 良好健康与福祉
学术指纹
探究 'Back-analyses of landfill instability induced by high water level: Case study of Shenzhen landfill' 的科研主题。它们共同构成独一无二的学术指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver