TY - JOUR
T1 - Automatic renal cortex segmentation using implicit shape registration and novel multiple surfaces graph search
AU - Li, Xiuli
AU - Chen, Xinjian
AU - Yao, Jianhua
AU - Zhang, Xing
AU - Yang, Fei
AU - Tian, Jian
PY - 2012
Y1 - 2012
N2 - In this paper, we present an automatic renal cortex segmentation approach using the implicit shape registration and novel multiple surfaces graph search. The proposed approach is based on a hierarchy system. First, the whole kidney is roughly initialized using an implicit shape registration method, with the shapes embedded in the space of Euclidean distance functions. Second, the outer and inner surfaces of renal cortex are extracted utilizing multiple surfaces graph searching, which is extended to allow for varying sampling distances and physical constraints to better separate the renal cortex and renal column. Third, a renal cortex refining procedure is applied to detect and reduce incorrect segmentation pixels around the renal pelvis, further improving the segmentation accuracy. The method was evaluated on 17 clinical computed tomography scans using the leave-one-out strategy with five metrics: Dice similarity coefficient (DSC), volumetric overlap error (OE), signed relative volume difference (SVD), average symmetric surface distance D avg, and average symmetric rms surface distance (D rms). The experimental results of DSC, OE, SVD, D avg, and D rms were 90.50% ±1.19%, 4.38% ± 3.93%, 2.37% ± 1.72%, 0.14 mm ± 0.09 mm , and 0.80 mm ± 0.64 mm, respectively. The results showed the feasibility, efficiency, and robustness of the proposed method.
AB - In this paper, we present an automatic renal cortex segmentation approach using the implicit shape registration and novel multiple surfaces graph search. The proposed approach is based on a hierarchy system. First, the whole kidney is roughly initialized using an implicit shape registration method, with the shapes embedded in the space of Euclidean distance functions. Second, the outer and inner surfaces of renal cortex are extracted utilizing multiple surfaces graph searching, which is extended to allow for varying sampling distances and physical constraints to better separate the renal cortex and renal column. Third, a renal cortex refining procedure is applied to detect and reduce incorrect segmentation pixels around the renal pelvis, further improving the segmentation accuracy. The method was evaluated on 17 clinical computed tomography scans using the leave-one-out strategy with five metrics: Dice similarity coefficient (DSC), volumetric overlap error (OE), signed relative volume difference (SVD), average symmetric surface distance D avg, and average symmetric rms surface distance (D rms). The experimental results of DSC, OE, SVD, D avg, and D rms were 90.50% ±1.19%, 4.38% ± 3.93%, 2.37% ± 1.72%, 0.14 mm ± 0.09 mm , and 0.80 mm ± 0.64 mm, respectively. The results showed the feasibility, efficiency, and robustness of the proposed method.
KW - Implicit shape registration
KW - multiple surfaces graph searching
KW - physical constraints
KW - renal cortex
KW - segmentation
UR - https://www.scopus.com/pages/publications/84867082069
U2 - 10.1109/TMI.2012.2203922
DO - 10.1109/TMI.2012.2203922
M3 - 文章
C2 - 22695346
AN - SCOPUS:84867082069
SN - 0278-0062
VL - 31
SP - 1849
EP - 1860
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 10
M1 - 6214612
ER -