N2 - BACKGROUND: Near-infrared imaging with indocyanine green has been used to guide lateral lymph node dissection, yet its efficacy and benefits need further investigation. OBJECTIVE: To investigate the efficacy and feasibility of near-infrared fluorescence imaging and angiography of the inferior vesical artery in laparoscopic lateral lymph node dissection. DESIGN: A prospective nonrandomized controlled study. SETTINGS: Single-center study. PATIENTS: Patients with lower rectal cancer who underwent total mesorectal excision plus lateral lymph node dissection. MAIN OUTCOME MEASURES: A cohort of 108 patients was enrolled. After propensity score matching, 29 patients in the near-infrared group and 50 patients in the non-near-infrared group were matched. The total number of harvested lateral lymph nodes, positive lateral lymph nodes, inferior vesical artery preservation, and postoperative urinary function were compared. RESULTS: After propensity score matching, both groups had similar baseline characteristics. The total number of harvested lateral lymph nodes in the near-infrared group was significantly higher (12 vs 9, p = 0.013), but positive lateral lymph nodes were similar between the 2 groups (1 vs 1, p = 0.439). The inferior vesical artery preservation ratio was significantly increased with the aid of indocyanine green angiography (93.1% vs 56.0%, p < 0.001). The non-near-infrared group required more days for urinary catheter removal than the near-infrared group (5 vs 4, p = 0.046). Urinary recatheterization tended to occur more frequently in the non-near-infrared group, with a marginally significant trend (16% vs 0%, p = 0.059). The non-near-infrared group tended to have more cases with residual urine volume ≥50 mL than the near-infrared group (20.0% vs 3.4%, p = 0.087), especially in the bilateral dissection subgroup (41.2% vs 0%, p = 0.041). LIMITATIONS: Small sample size. CONCLUSIONS: Near-infrared imaging increased the number of harvested lateral lymph nodes, whereas real-time indocyanine green fluorescence angiography ensured the preservation of the inferior vesical artery and tended to improve postoperative urinary function.
AB - BACKGROUND: Near-infrared imaging with indocyanine green has been used to guide lateral lymph node dissection, yet its efficacy and benefits need further investigation. OBJECTIVE: To investigate the efficacy and feasibility of near-infrared fluorescence imaging and angiography of the inferior vesical artery in laparoscopic lateral lymph node dissection. DESIGN: A prospective nonrandomized controlled study. SETTINGS: Single-center study. PATIENTS: Patients with lower rectal cancer who underwent total mesorectal excision plus lateral lymph node dissection. MAIN OUTCOME MEASURES: A cohort of 108 patients was enrolled. After propensity score matching, 29 patients in the near-infrared group and 50 patients in the non-near-infrared group were matched. The total number of harvested lateral lymph nodes, positive lateral lymph nodes, inferior vesical artery preservation, and postoperative urinary function were compared. RESULTS: After propensity score matching, both groups had similar baseline characteristics. The total number of harvested lateral lymph nodes in the near-infrared group was significantly higher (12 vs 9, p = 0.013), but positive lateral lymph nodes were similar between the 2 groups (1 vs 1, p = 0.439). The inferior vesical artery preservation ratio was significantly increased with the aid of indocyanine green angiography (93.1% vs 56.0%, p < 0.001). The non-near-infrared group required more days for urinary catheter removal than the near-infrared group (5 vs 4, p = 0.046). Urinary recatheterization tended to occur more frequently in the non-near-infrared group, with a marginally significant trend (16% vs 0%, p = 0.059). The non-near-infrared group tended to have more cases with residual urine volume ≥50 mL than the near-infrared group (20.0% vs 3.4%, p = 0.087), especially in the bilateral dissection subgroup (41.2% vs 0%, p = 0.041). LIMITATIONS: Small sample size. CONCLUSIONS: Near-infrared imaging increased the number of harvested lateral lymph nodes, whereas real-time indocyanine green fluorescence angiography ensured the preservation of the inferior vesical artery and tended to improve postoperative urinary function.
KW - Indocyanine green
KW - Inferior vesical artery
KW - Lateral lymph node dissection
KW - Near-infrared imaging
KW - Rectal cancer
KW - Urinary function
UR - https://www.scopus.com/pages/publications/85179650266
U2 - 10.1097/DCR.0000000000002926
DO - 10.1097/DCR.0000000000002926
M3 - 文章
C2 - 38091416
AN - SCOPUS:85179650266
SN - 0012-3706
VL - 67
SP - 175
EP - 184
JO - Diseases of the Colon and Rectum
JF - Diseases of the Colon and Rectum
IS - 1
ER -