TY - JOUR
T1 - Analysis and measurement of magnetic noise for tesla shielding based on superconducting coils applied to SERF magnetometer
AU - Gao, Yanan
AU - Ma, Danyue
AU - Li, Mengchao
AU - Zhang, Mengshi
AU - Chen, Yunbo
AU - Han, Changmi
AU - Wang, Yutian
AU - Fang, Xiujie
AU - Dou, Yao
AU - Wang, Kun
N1 - Publisher Copyright:
© 2024
PY - 2025/1
Y1 - 2025/1
N2 - Tesla Shielding (TS) is closed superconducting coils composed of superconducting tape, designed to resist changing magnetic fields, thereby achieving magnetic shielding. TS, optically transparent, is suitable for integration with spin exchange relaxation-Free (SERF) magnetometers, thereby improving the sensitivity of SERF magnetometers. However, no prior research has been conducted on the magnetic noise of TS. Noise source identification was conducted on the superconducting tapes used in the TS. We modeled the magnetic noise of superconducting coils, analyzed the the relationship between geometric parameters and magnetic noise of coils, and proposed methods to suppress magnetic noise. Finally, we established a measurement system to measure the magnetic noise of superconducting coils. The results confirm the feasibility of the magnetic noise calculation model and the effectiveness of the methods for suppressing magnetic noise. This study can guide the design of TS, which is important for improving the sensitivity of SERF magnetometers.
AB - Tesla Shielding (TS) is closed superconducting coils composed of superconducting tape, designed to resist changing magnetic fields, thereby achieving magnetic shielding. TS, optically transparent, is suitable for integration with spin exchange relaxation-Free (SERF) magnetometers, thereby improving the sensitivity of SERF magnetometers. However, no prior research has been conducted on the magnetic noise of TS. Noise source identification was conducted on the superconducting tapes used in the TS. We modeled the magnetic noise of superconducting coils, analyzed the the relationship between geometric parameters and magnetic noise of coils, and proposed methods to suppress magnetic noise. Finally, we established a measurement system to measure the magnetic noise of superconducting coils. The results confirm the feasibility of the magnetic noise calculation model and the effectiveness of the methods for suppressing magnetic noise. This study can guide the design of TS, which is important for improving the sensitivity of SERF magnetometers.
KW - Magnetic noise
KW - Magnetic shield
KW - SERF magnetometer
KW - Superconducting coil
UR - https://www.scopus.com/pages/publications/85206290003
U2 - 10.1016/j.measurement.2024.115971
DO - 10.1016/j.measurement.2024.115971
M3 - 文章
AN - SCOPUS:85206290003
SN - 0263-2241
VL - 242
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 115971
ER -