跳到主要导航 跳到搜索 跳到主要内容

An optimal inspection and replacement policy for a two-unit system

  • Beijing Institute of Technology

科研成果: 期刊稿件文章同行评审

摘要

We study a preventive maintenance policy for a system composed of two units, a binary state unit and a three-state unit. Failures of both units are hard and self-announcing. The intermediate, defective state for the second unit can be regarded as a signal of pending failures. Unit 2 is inspected when its age attains integral multiples of interval s and when unit 1 fails, and preventive replacement is immediate once the defective state is revealed. This strategy could be extended by further providing preventive replacement for the first unit. A case study on an offshore wind turbine is presented for illustration. We find that opportunistic maintenance schemed for both units could effectively reduce the maintenance cost.

源语言英语
页(从-至)766-776
页数11
期刊Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability
232
6
DOI
出版状态已出版 - 1 12月 2018

指纹

探究 'An optimal inspection and replacement policy for a two-unit system' 的科研主题。它们共同构成独一无二的指纹。

引用此