摘要
To observe the effects of active heating system for spacesuit gloves on extravehicular working performance. After analyzing the factors with gloves influence on the working performance, the effects of active heating system for gloves were studied experimentally with aspects to fatigue, hand strength, dexterity and tactile sensing. The results are: 1) Heating-system had not influence to grip; 2) Heating-system had 17% influence to fatigue except specific person; 3) Nut assembly and nipping pin showed that heating-system had little influence to dexterity; 4)Apperceiving shape of object and two-point distance showed heating-system had little influence to tactility. The active heating method is rational and has little influence on working performance.
| 源语言 | 英语 |
|---|---|
| 页(从-至) | 47-51 |
| 页数 | 5 |
| 期刊 | Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering |
| 卷 | 18 |
| 期 | 1 |
| 出版状态 | 已出版 - 2月 2005 |