跳到主要导航 跳到搜索 跳到主要内容

An accurate calibration method for line structured light vision sensor

  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

A calibration method for line structured light vision sensor that does not require extraction of control points in the light plane is proposed to solve the calibration problem of line structured light vision sensor. The planar target is placed in front of the vision sensor several times. The Plücker matrix of light strip on the target plane is computed. The equation of the light plane in the camera coordinate frame can be solved by combining the Plücker matrixs of the light stripe on the target plane at different positions. The maximum likelihood estimation of the light plane equation is obtained through nonlinear optimization. The proposed method is robust and accurate, because all of the light stripe image points are used to determine the equation of the light plane. Experimental results show that, compared with that of existing calibration methods, the calibration accuracy of the proposed method improves about 30%.

源语言英语
页(从-至)3124-3128
页数5
期刊Guangxue Xuebao/Acta Optica Sinica
29
11
DOI
出版状态已出版 - 11月 2009

学术指纹

探究 'An accurate calibration method for line structured light vision sensor' 的科研主题。它们共同构成独一无二的学术指纹。

引用此