跳到主要导航 跳到搜索 跳到主要内容

A Novel Dynamic Measurement Method for Rotor-Stator Axial Clearance

  • Beihang University

科研成果: 期刊稿件文章同行评审

摘要

Accurate measurement of the axial clearance between the rotor and stator in an aeroengine is crucial for precise engine design and aerodynamic analysis. It also provides a significant reference for correcting measurements obtained through other noncontact methods. This article proposes a triangulation method based on time of arrival (TMBT) for measuring axial clearance, which can simultaneously measure rotor speed and has the potential to replace traditional once-per-revolution (OPR) sensors. The mechanism of measurement error is analyzed, and methods for error estimation and correction are proposed. A simulated rotor test bench was set up in the laboratory to achieve dynamic calibration and performance testing of the sensor and to verify the effectiveness of the error estimation and correction methods. Experimental results show that the measurement accuracy of this method is better than 0.05 mm (for a range of 2.5-8.0 mm) and better than 1.5% (for a range of 2.5-11.0 mm). The proposed error estimation and correction methods effectively estimate and correct measurement errors caused by sensor installation positional offsets.

源语言英语
文章编号7502413
期刊IEEE Transactions on Instrumentation and Measurement
74
DOI
出版状态已出版 - 2025

指纹

探究 'A Novel Dynamic Measurement Method for Rotor-Stator Axial Clearance' 的科研主题。它们共同构成独一无二的指纹。

引用此