TY - JOUR
T1 - A Novel Adaptive Parameter Search Elastic Net Method for Fluorescent Molecular Tomography
AU - Wang, Hanfan
AU - Bian, Chang
AU - Kong, Lingxin
AU - An, Yu
AU - Du, Yang
AU - Tian, Jie
N1 - Publisher Copyright:
© 1982-2012 IEEE.
PY - 2021/5
Y1 - 2021/5
N2 - Fluorescence molecular tomography (FMT) is a new type of medical imaging technology that can quantitatively reconstruct the three-dimensional distribution of fluorescent probes in vivo. Traditional Lp norm regularization techniques used in FMT reconstruction often face problems such as over-sparseness, over-smoothness, spatial discontinuity, and poor robustness. To address these problems, this paper proposes an adaptive parameter search elastic net (APSEN) method that is based on elastic net regularization, using weight parameters to combine the L1 and L2 norms. For the selection of elastic net weight parameters, this approach introduces the L0 norm of valid reconstruction results and the L2 norm of the residual vector, which are used to adjust the weight parameters adaptively. To verify the proposed method, a series of numerical simulation experiments were performed using digital mice with tumors as experimental subjects, and in vivo experiments of liver tumors were also conducted. The results showed that, compared with the state-of-the-art methods with different light source sizes or distances, Gaussian noise of 5%-25%, and the brute-force parameter search method, the APSEN method has better location accuracy, spatial resolution, fluorescence yield recovery ability, morphological characteristics, and robustness. Furthermore, the in vivo experiments demonstrated the applicability of APSEN for FMT.
AB - Fluorescence molecular tomography (FMT) is a new type of medical imaging technology that can quantitatively reconstruct the three-dimensional distribution of fluorescent probes in vivo. Traditional Lp norm regularization techniques used in FMT reconstruction often face problems such as over-sparseness, over-smoothness, spatial discontinuity, and poor robustness. To address these problems, this paper proposes an adaptive parameter search elastic net (APSEN) method that is based on elastic net regularization, using weight parameters to combine the L1 and L2 norms. For the selection of elastic net weight parameters, this approach introduces the L0 norm of valid reconstruction results and the L2 norm of the residual vector, which are used to adjust the weight parameters adaptively. To verify the proposed method, a series of numerical simulation experiments were performed using digital mice with tumors as experimental subjects, and in vivo experiments of liver tumors were also conducted. The results showed that, compared with the state-of-the-art methods with different light source sizes or distances, Gaussian noise of 5%-25%, and the brute-force parameter search method, the APSEN method has better location accuracy, spatial resolution, fluorescence yield recovery ability, morphological characteristics, and robustness. Furthermore, the in vivo experiments demonstrated the applicability of APSEN for FMT.
KW - Fluorescence molecular tomography
KW - adaptive parameter search
KW - elastic net
UR - https://www.scopus.com/pages/publications/85101488672
U2 - 10.1109/TMI.2021.3057704
DO - 10.1109/TMI.2021.3057704
M3 - 文章
C2 - 33556004
AN - SCOPUS:85101488672
SN - 0278-0062
VL - 40
SP - 1484
EP - 1498
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 5
M1 - 9349471
ER -