TY - JOUR
T1 - A new practical model of an objective lens with assembling clearance for transmission electron microscope
AU - Li, Wen Ping
AU - Gui, Li Jiang
AU - Wu, Jian
AU - Dong, Quan Lin
AU - Yao, Jun En
PY - 2011/3/1
Y1 - 2011/3/1
N2 - A new objective lens model including magnetic pole pieces, coil windings, magnetic circuit as well as the assembling clearance between the pole piece and magnetic circuit is developed to obtain high simulation precision. The calculation is based on the second-order finite element method (SOFEM) with the measured BH magnetization curves of the lens materials. The magnetic pole pieces and magnetic circuit are firstly optimized to reduce the lens saturation and obtain minimum spherical aberration coefficient, then modified to release the magnetic flux leakage caused by the increased clearance. In the end, an example is given for a 200 kV TEM with the point resolution of 0.25 nm and off-axis aberration coefficients at the image plane are calculated for dynamic correction. Results show that the magnetic circuit is unsaturated and the saturated area is only 0.8×4.8 mm2 around the lower pole piece with a maximum magnetic flux density of 2.537 T. This model can reduce the magnetic flux leakage and obtain the point resolution with smaller excitation. The calculation also shows that the off-axis aberrations require correcting dynamically to acquire fine image quality under low system magnification.
AB - A new objective lens model including magnetic pole pieces, coil windings, magnetic circuit as well as the assembling clearance between the pole piece and magnetic circuit is developed to obtain high simulation precision. The calculation is based on the second-order finite element method (SOFEM) with the measured BH magnetization curves of the lens materials. The magnetic pole pieces and magnetic circuit are firstly optimized to reduce the lens saturation and obtain minimum spherical aberration coefficient, then modified to release the magnetic flux leakage caused by the increased clearance. In the end, an example is given for a 200 kV TEM with the point resolution of 0.25 nm and off-axis aberration coefficients at the image plane are calculated for dynamic correction. Results show that the magnetic circuit is unsaturated and the saturated area is only 0.8×4.8 mm2 around the lower pole piece with a maximum magnetic flux density of 2.537 T. This model can reduce the magnetic flux leakage and obtain the point resolution with smaller excitation. The calculation also shows that the off-axis aberrations require correcting dynamically to acquire fine image quality under low system magnification.
KW - Assembling clearance
KW - Asymmetric magnetic flux leakage
KW - Magnetic saturation effect
KW - Second-order finite element method
UR - https://www.scopus.com/pages/publications/79551501689
U2 - 10.1016/j.nima.2010.10.074
DO - 10.1016/j.nima.2010.10.074
M3 - 文章
AN - SCOPUS:79551501689
SN - 0168-9002
VL - 631
SP - 134
EP - 137
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
IS - 1
ER -