摘要
This paper reports a low-cycle fatigue test device for micro-cantilevers, which are widely used in micro scale structures. The working principle of the device is based on the phenomenon that a micro-cantilever can be set into self-excited vibration between two electrodes under DC voltage. Compared with previous devices, this simple device can produce large strain amplitude on non-notched specimens, and allows a batch of specimens to be tested simultaneously. Forty-two micro-cantilever specimens were tested and their fatigue fracture surfaces exhibit typical low cycle fatigue characteristics. As such, the device is very attractive for future fatigue investigation for micro scale structures.
| 源语言 | 英语 |
|---|---|
| 文章编号 | 105005 |
| 期刊 | Review of Scientific Instruments |
| 卷 | 85 |
| 期 | 10 |
| DOI | |
| 出版状态 | 已出版 - 1 10月 2014 |
指纹
探究 'A low cycle fatigue test device for micro-cantilevers based on self-excited vibration principle' 的科研主题。它们共同构成独一无二的指纹。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver