A low cycle fatigue test device for micro-cantilevers based on self-excited vibration principle

科研成果: 期刊稿件文章同行评审

摘要

This paper reports a low-cycle fatigue test device for micro-cantilevers, which are widely used in micro scale structures. The working principle of the device is based on the phenomenon that a micro-cantilever can be set into self-excited vibration between two electrodes under DC voltage. Compared with previous devices, this simple device can produce large strain amplitude on non-notched specimens, and allows a batch of specimens to be tested simultaneously. Forty-two micro-cantilever specimens were tested and their fatigue fracture surfaces exhibit typical low cycle fatigue characteristics. As such, the device is very attractive for future fatigue investigation for micro scale structures.

源语言英语
文章编号105005
期刊Review of Scientific Instruments
85
10
DOI
出版状态已出版 - 1 10月 2014