T1 - A Highly Integrated High-Resolution Cone Beam CT System for Intraoperative Imaging in Minimally Invasive Cochlear Surgery
AU - Jin, Peng
AU - Zhang, Shaobo
AU - Wang, Xianghong
AU - Xu, Lei
AU - Jiang, Yin
AU - Niu, Tianye
AU - Zhao, Wei
N1 - Publisher Copyright:
© 1963-2012 IEEE.
PY - 2025
Y1 - 2025
N2 - Utilizing cone beam computed tomography (CBCT) to monitor minimally invasive surgery (MIS) is essential for ensuring surgical safety, particularly in high-precision procedures such as cochlear implantation (CI). Existing CBCT systems—including whole-body units and those tailored for ear diagnostics, dentistry, or head imaging—are typically bulky and poorly integrated, limiting their utility in intraoperative environments. To address this gap, we propose a highly integrated, high-resolution CBCT system specifically designed for intraoperative cochlear MIS. The system incorporates a dual-joint robotic structure, enabling both compact integration and mechanical flexibility by allowing the imaging chain to be folded to accommodate other surgical instruments. From a measurement perspective, the system is engineered to optimize key imaging performance parameters through a balance between field of view (FOV), spatial resolution, and mechanical stability. Geometric parameters were quantitatively optimized to minimize rotational bending moments, ensuring consistent and precise scanning. Imaging performance was systematically assessed using four types of phantoms. Quantitative measurements demonstrated a spatial resolution of 150 μm (3.3 lp/mm), a contrast-to-noise ratio (CNR) of 8.63 at a 2.65% contrast level, and a 3-D uniformity deviation (UD) of 1.8%. In addition, qualitative validation was conducted using a live pig and a human cadaver head to simulate real clinical conditions. These findings highlight the system’s capability to deliver accurate, repeatable, and measurement-driven intraoperative imaging, offering enhanced safety and precision for cochlear MIS. The work contributes not only to imaging system integration but also to quantitative measurement methodology aligned with the focus of instrumentation and measurement research.
AB - Utilizing cone beam computed tomography (CBCT) to monitor minimally invasive surgery (MIS) is essential for ensuring surgical safety, particularly in high-precision procedures such as cochlear implantation (CI). Existing CBCT systems—including whole-body units and those tailored for ear diagnostics, dentistry, or head imaging—are typically bulky and poorly integrated, limiting their utility in intraoperative environments. To address this gap, we propose a highly integrated, high-resolution CBCT system specifically designed for intraoperative cochlear MIS. The system incorporates a dual-joint robotic structure, enabling both compact integration and mechanical flexibility by allowing the imaging chain to be folded to accommodate other surgical instruments. From a measurement perspective, the system is engineered to optimize key imaging performance parameters through a balance between field of view (FOV), spatial resolution, and mechanical stability. Geometric parameters were quantitatively optimized to minimize rotational bending moments, ensuring consistent and precise scanning. Imaging performance was systematically assessed using four types of phantoms. Quantitative measurements demonstrated a spatial resolution of 150 μm (3.3 lp/mm), a contrast-to-noise ratio (CNR) of 8.63 at a 2.65% contrast level, and a 3-D uniformity deviation (UD) of 1.8%. In addition, qualitative validation was conducted using a live pig and a human cadaver head to simulate real clinical conditions. These findings highlight the system’s capability to deliver accurate, repeatable, and measurement-driven intraoperative imaging, offering enhanced safety and precision for cochlear MIS. The work contributes not only to imaging system integration but also to quantitative measurement methodology aligned with the focus of instrumentation and measurement research.
KW - Cochlear implantation (CI)
KW - cone beam computed tomography (CBCT)
KW - high integration
KW - high resolution
KW - intraoperative imaging
UR - https://www.scopus.com/pages/publications/105015154805
U2 - 10.1109/TIM.2025.3606069
DO - 10.1109/TIM.2025.3606069
M3 - 文章
AN - SCOPUS:105015154805
SN - 0018-9456
VL - 74
JO - IEEE Transactions on Instrumentation and Measurement
JF - IEEE Transactions on Instrumentation and Measurement
M1 - 4017413
ER -