跳到主要导航 跳到搜索 跳到主要内容

A 402 MHz and 1.73-VCE Resonance Regulating Rectifier With On-Chip Antennas for Bioimplants

  • Guoao Liu
  • , Yuanqi Hu*
  • *此作品的通讯作者
  • Beihang University

科研成果: 期刊稿件 › 文章 › 同行评审

摘要

In this paper, a wireless power transfer (WPT) system composed of a voltage-mode fully integrated resonance regulating rectifier (IR3) and an on-chip antenna running at 402 MHz has been designed for bioimplants in deep tissue. The proposed IR3, including a 200 pF decoupling capacitor, is implemented in a 0.22 mm2 active area in the 180-nm CMOS process. A charging duration based regulation compensation circuit offers a low ripple factor of 0.3% at a 1.8 V output voltage and a high voltage conversion efficiency (VCE) of 1.73 to overcome the low inductive coupling coefficient (under 0.01) due to the deep implant scenario. And a clock gating VCDL-based on-&-off delay compensation scheme is proposed to compensate for the phase error of the IR3. Performing rectification and regulation simultaneously in a single stage, the IR3 effectively enhances power conversion efficiency. The whole system achieves a power conversion efficiency (PCE) of 65% with a 1.5 mW load. In addition, digital control-based compensation circuits also improve its transient response performance, the 1% setting time is only 6.9 μs when the load changes from 65 μW to 1.5 mW.

源语言英语
页(从-至)968-980
页数13
期刊IEEE Transactions on Biomedical Circuits and Systems
卷19
期5
DOI
出版状态已出版 - 2025

学术指纹

探究 'A 402 MHz and 1.73-VCE Resonance Regulating Rectifier With On-Chip Antennas for Bioimplants' 的科研主题。它们共同构成独一无二的学术指纹。