跳到主要导航 跳到搜索 跳到主要内容

3D imaging with electrical capacitance tomography in cyclone separators

  • Hai Gang Wang*
  • , Shi Liu
  • , Fan Jiang
  • , Wu Qiang Yang
  • *此作品的通讯作者
  • CAS - Institute of Engineering Thermophysics
  • University of Manchester

科研成果: 期刊稿件文章同行评审

摘要

Electrical capacitance tomography (ECT) technology with 12-electrodes has been developed to provide 2D images of a cross section of cyclone separators. For some applications, e.g. to investigate gas/solids distribution in the cyclone separators, 3D images provide valuable information. This paper presents a method of reconstructing 3D images, using Visual C++ and Open-GL, from 2D images obtained from the ECT system. The feasibility and reliability of this method are verified by the experimental results and Computational Fluid Dynamics (CFD) simulation results.

源语言英语
页(从-至)177-179
页数3
期刊Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
27
1
出版状态已出版 - 1月 2006
已对外发布

引用此