跳到主要导航 跳到搜索 跳到主要内容

人工智能技术在胎儿超声心动图四腔心切面筛查中的应用

  • Xiaoxue Zhou
  • , Yingying Zhang
  • , Ye Zhang
  • , Jiancheng Han
  • , Xiaowei Liu
  • , Xiaoyan Gu
  • , Lin Sun
  • , Ying Zhao
  • , Yanping Ruan
  • , Yihua He*
  • *此作品的通讯作者
  • Capital Medical University

科研成果: 期刊稿件文章同行评审

摘要

Objective: To investigate the value of artificial intelligence in screening normal or abnormal four-chamber view of the fetal heart. Methods: Selecting 3 996 pictures of normal and abnormal end systolic four chamber views and 450 video clips from the database of Beijing Key Laboratory of Fetal Heart Disease Maternal and Fetal Medicine Research in Beijing Anzhen Hospital as training set, test set and verification set to train, test and verify DGACNN model. ①Comparing DGACNN, DGACNN-ALOCC and other classification models(Densenet, Resnet50, InceptionV3, InceptionResnetV2) to detect the model with the most advanced level by recognizing 200 normal pictures and 200 abnormal pictures. ②Fetal echocardiographers were divided into three groups according to their experiences: primary, intermediate and advanced, 3 doctors in each group, and comparing the average score between each group or three groups and DGACNN by recognizing 100 normal pictures and 100 abnormal pictures. Results: ①When the the false positive rate(FPR) was in the range of 20%, the recognition accuracy of DGACNN was the highest with 0.850, the recognition accuracy of other models were DGACNN-ALOCC 0.835, Densenet 0.780, Resnet50 0.700, InceptionV3 0.670, InceptionResnetV2 0.650, respectively. ②When FPR was in the range of 20%, the area under ROC curve of DGACNN was the largest with 0.881, the area under ROC curve of other models were DGACNN-ALOCC 0.864, Densenet 0.850, Resnet50 0.822, Inceptionv3 0.779, InceptionResnetV2 0.703, respectively. ③When the FPR was in the range of 20%, the average recognition accuracy of the senior fetal echocardiographer group was the highest with 0.863, followed by DGACNN 0.840, which was higher than the average recognition accuracy of the primary and intermediate groups with 0.760, 0.807; the average recognition accuracy of DGACNN was higher than the total average recognition accuracy of the primary, intermediate and advanced groups with 0.810. Conclusions: Artificial intelligence is accessible in screening four chamber view of fetal echocardiography, with high recognition accuracy.

投稿的翻译标题Application of artificial intelligence in screening the four-chamber view of fetal echocardiography
源语言繁体中文
页(从-至)668-672
页数5
期刊Chinese Journal of Ultrasonography
29
8
DOI
出版状态已出版 - 25 8月 2020

关键词

  • Artificial intelligence
  • Fetal echocardiography
  • Four-chamber view
  • Screen

指纹

探究 '人工智能技术在胎儿超声心动图四腔心切面筛查中的应用' 的科研主题。它们共同构成独一无二的指纹。

引用此