@inproceedings{8fcea629398f4600b5bb8917163edceb,
title = "Wet gas flow modeling for the straight section of throat-extended Venturi meter",
abstract = "In this paper, wet gas flow modeling for the straight section of a throat-extended Venturi meter was studied. A static model based on the separated flow theory was presented. Experiments were carried out within static pressure range of 0.26∼0.86 MPa, gas volumetric flowrate range of 80∼120 m3/h, water volumetric flowrate range of 0.3∼4.5 m3/h and quality range of 0.07∼0.36. It was obtained that the root mean square of the relative errors of the DP over the straight section calculated from the static model was 8.82\%.",
keywords = "Differential pressure (DP), Flow modeling, Straight section, Throat-extended venturi meter (TEVM), Wet gas metering",
author = "Wanlu Zhou and Lijun Xu and Xiaomin Li",
year = "2010",
doi = "10.1109/IMTC.2010.5488011",
language = "英语",
isbn = "9781424428335",
series = "2010 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2010 - Proceedings",
pages = "229--233",
booktitle = "2010 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2010 - Proceedings",
note = "2010 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2010 ; Conference date: 03-05-2010 Through 06-05-2010",
}