Abstract
After isothermal exposure at 1050 °C, uneven growth of thermally grown oxide (TGO) was observed at peak and valley positions of rough top coat/TGO interface. A statistical, quantitative analysis on uneven TGO and its evolution with oxidation time were presented. The stress states in the vicinity of uneven TGO were investigated using a finite element (FE) method. The results show that the TGO at peak and valley locations obeys exponential growth. The TGO is thicker at peaks than at valleys. A significant difference in the stress distribution exists for even and uneven TGO.
| Original language | English |
|---|---|
| Pages (from-to) | 3088-3091 |
| Number of pages | 4 |
| Journal | Surface and Coatings Technology |
| Volume | 203 |
| Issue number | 20-21 |
| DOIs | |
| State | Published - 15 Jul 2009 |
Keywords
- Plasma spraying
- Thermal barrier coating
- Thermally grown oxide
Fingerprint
Dive into the research topics of 'Uneven growth of thermally grown oxide and stress distribution in plasma-sprayed thermal barrier coatings'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver