Understanding of the corrosion protection by V(IV) conversion coatings from a sol-gel perspective

  • Zhiqiang Gao
  • , Dawei Zhang*
  • , Lifeng Hou
  • , Xiaogang Li
  • , Yinghui Wei
  • *Corresponding author for this work
  • Taiyuan University of Technology
  • University of Science and Technology Beijing
  • Taiyuan University of Science and Technology

Research output: Contribution to journalArticlepeer-review

Abstract

The mechanisms by which V(IV) (tetravalent vanadium) as a film ingredient protects the surface remain dim. This work gives a clear and concise understanding of the corrosion protection of hot-dip galvanized (HDG) steel by vanadyl oxalate (VOC2O4) conversion coatings from a sol-gel perspective, along with data from X-ray photoelectron spectroscopy (XPS) surface characterization, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) measurements. An elaborate integration of experimental results and thermodynamic analysis suggests that the protection can be exerted persistently as long as V(IV) is available in sufficient quantities at susceptible sites to maintain hydrolysis, condensation, and polymerization.

Original languageEnglish
Article number108196
JournalCorrosion Science
Volume161
DOIs
StatePublished - Dec 2019
Externally publishedYes

Keywords

  • Corrosion
  • Hot-dip galvanized steel
  • Polarization
  • Sol-gel
  • Vanadate

Fingerprint