Skip to main navigation Skip to search Skip to main content

UBO Detector – A cluster-based, fully automated pipeline for extracting white matter hyperintensities

  • Jiyang Jiang
  • , Tao Liu
  • , Wanlin Zhu
  • , Rebecca Koncz
  • , Hao Liu
  • , Teresa Lee
  • , Perminder S. Sachdev
  • , Wei Wen*
  • *Corresponding author for this work
  • University of New South Wales
  • Beihang University
  • Prince of Wales Hospital

Research output: Contribution to journalArticlepeer-review

Abstract

We present ‘UBO Detector’ a cluster-based, fully automated pipeline for extracting and calculating variables for regions of white matter hyperintensities (WMH) (available for download at https://cheba.unsw.edu.au/group/neuroimaging-pipeline). It takes T1-weighted and fluid attenuated inversion recovery (FLAIR) scans as input, and SPM12 and FSL functions are utilised for pre-processing. The candidate clusters are then generated by FMRIB's Automated Segmentation Tool (FAST). A supervised machine learning algorithm, k-nearest neighbor (k-NN), is applied to determine whether the candidate clusters are WMH or non-WMH. UBO Detector generates both image and text (volumes and the number of WMH clusters) outputs for whole brain, periventricular, deep, and lobar WMH, as well as WMH in arterial territories. The computation time for each brain is approximately 15 min. We validated the performance of UBO Detector by showing a) high segmentation (similarity index (SI) = 0.848) and volumetric (intraclass correlation coefficient (ICC) = 0.985) agreement between the UBO Detector-derived and manually traced WMH; b) highly correlated (r2 > 0.9) and a steady increase of WMH volumes over time; and c) significant associations of periventricular (t = 22.591, p < 0.001) and deep (t = 14.523, p < 0.001) WMH volumes generated by UBO Detector with Fazekas rating scores. With parallel computing enabled in UBO Detector, the processing can take advantage of multi-core CPU's that are commonly available on workstations. In conclusion, UBO Detector is a reliable, efficient and fully automated WMH segmentation pipeline.

Original languageEnglish
Pages (from-to)539-549
Number of pages11
JournalNeuroImage
Volume174
DOIs
StatePublished - 1 Jul 2018

Keywords

  • Automated segmentation pipeline
  • White matter hyperintensities
  • k-nearest neighbours

Fingerprint

Dive into the research topics of 'UBO Detector – A cluster-based, fully automated pipeline for extracting white matter hyperintensities'. Together they form a unique fingerprint.

Cite this